YC1893D Meter Test Bench With 12 Positions Scanning Head YCG-2-series
YC1893D Meter Test Bench with 12 Positions
Description:
-
The meter test system supports the testing of mechanical meters, electromechanical meters, and electronic meters, offering automatic, semi-automatic, or manual operation to meet various testing needs.
-
Compatible with multiple wiring configurations including 3P4W, 3P3W, and 1P2W, suitable for wide utility applications.
-
Supports comprehensive testing modes: active power, reactive power, and cross-connected reactive power.
-
Capable of simultaneously testing meters with the same specifications but different meter constants, improving productivity.
-
Features automatic positioning of the rotor mark on mechanical meters, increasing efficiency and reducing manual intervention.
-
Includes starting and creeping tests as part of standard verification routines.
-
Optional neutral current test is available to meet extended testing requirements.
-
Supports optional ICT installation at each meter position, enabling precise testing of three-phase meters with closed current-voltage (I-P) links.
-
Equipped with protection functions against overload, voltage short circuit, and current open circuit, ensuring safety during operation.
-
The swinging scanning head design simplifies control and enhances ease of operation.
-
Constructed with lightweight aluminum alloy, offering high strength, corrosion resistance, and easy mobility—ideal for a wide range of working environments.
-
The testing software features a user-friendly interface, compatible with Windows 2000 / XP / 7 / 8 / 10, and supports multilingual customization for easy use and training.
-
Software includes all essential testing modules for modern energy meters: error test, harmonic test, demand test, and influence quantity test, ensuring complete and reliable performance.
Specifications
|
Voltage |
|
|
Test voltage output (Phase-Neutral) |
3x(24 – 300 V) |
|
Power of the voltage output |
3×1000VA |
|
Resolution |
Better than 0.01% of full scale value of range |
|
Setting accuracy |
Better than 0.05% at the final range value |
|
Stability |
Better than 0.005%/h (integration time 150 s) |
|
Load regulation from 0-max. load |
< 0.01% |
|
Distortion factor |
< 0.3% for linear resistance load |
|
Harmonics |
2nd – 21st free programmable |
|
Current |
|
|
Test current output |
1 mA – 120 A |
|
Power of the current output |
3×2000VA |
|
Resolution |
Better than 0.01% of full scale value of range |
|
Setting accuracy |
Better than 0.05% at the final range value |
|
Stability |
Better than 0.005%/h (integration time 150 s) |
|
Load regulation from 0-max. load |
< 0.01% |
|
Distortion factor |
< 0.3% for linear resistance load |
|
Harmonics |
2nd – 21st free programmable |
|
Phase angle |
|
|
Range |
0 -- 360° |
|
Resolution |
0.01° |
|
Setting accuracy |
0.1° |
|
Frequency |
|
|
Range |
45 Hz – 65 Hz |
|
Resolution |
0.01 Hz |
Get in Touch