YC1893D IEC 60736 Automatic Three-Phase Energy Meter Test Equipment with 24 Positions and 0.05% Accuracy
Price:
negotiation
MOQ:
1 pcs
Delivery Time:
30 days after order confirmed
Brand:
GENY
Product Description
YC1893D IEC 60736 Automatic Three-Phase Energy Meter Test Equipment
GENY meter test systems leverage state-of-the-art electronic metrology and modular architecture, integrating precision reference standards with high-stability power amplifiers to meet demanding requirements of energy-meter manufacturers, power utilities, metrology laboratories, inspection authorities, and industrial test facilities.
System Configuration
The YC1893D meter test system is a fully automatic test system for calibration of both single-phase and three-phase electric energy meters, comprising:
- Three-phase power source with high stability
- Three-phase reference standard meter for precision measurement
- Meter suspension test rack with 24 positions
- Tariffs control system with fixed voltages, optical port reader, and ripple control box
- Complete PC and software control system
- All necessary components for comprehensive testing
Compliance Standards
The YC1893D system is fully compliant with IEC 60736 and suitable for testing meters according to:
- IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
- IEC 62056 communication protocols
- EN 50470-1, EN 50470-2, EN-50470-3 European standards
- IEC 61010 safety requirements
Technical Specifications
| Parameter | Specification |
|---|---|
| System Configuration | |
| Number of meter positions | 24 |
| Accuracy | 0.05 / 0.02 |
| Power Source | YCS-103-1200 |
| Standard Meter | SZ03A-K6 / SZ03A-K8 / Radian RD-33 |
| Scanning Head | YCG-S Series |
| Voltage Output | |
| Test voltage output (Phase-Neutral) | 3×(24V~288V) or customized |
| Power of voltage output | Max. 3×500VA |
| Resolution | Better than 0.01% of full scale value |
| Setting accuracy | Better than 0.05% at final range value |
| Stability | Better than 0.005%/h (integration time 150s) |
| Load regulation (0~max. load) | Better than 0.01% |
| Distortion factor | Better than 0.3% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Current Output | |
| Test current output | 3×(1mA-100A) |
| Power of current output | Max. 3×750VA |
| Resolution | Better than 0.01% of full scale value |
| Setting accuracy | Better than 0.05% at final range value |
| Stability | Better than 0.005%/h (integration time 150s) |
| Load regulation (0~max. load) | Better than 0.01% |
| Distortion factor | Better than 0.3% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Additional Parameters | |
| Phase angle range | 0~360° |
| Phase angle resolution | 0.01° |
| Phase angle setting accuracy | 0.1° |
| Frequency range | 45Hz~65Hz |
| Frequency resolution | 0.01Hz |
| Error display type | Red LED |
| Error display resolution | 8 digitals |
| Voltage supply | 3×220/380V±10% (or customized) 50/60Hz ±2Hz |
| Ambient temperature | -10°C~+40°C |
| Relative humidity | 35%~85% |
Product Images