Long-Term Stability ±0.5% FS/Year Micro Differential Pressure Meter
Price:
$125.00 - $135.00/units
MOQ:
10 units
Delivery Time:
Negotiable
Brand:
IVANPER
Product Description
Product Description

Specification
Packing & Delivery


cable or screw terminals Accuracy: ±1.0%
FS(±2.0%FS@25Pa range) Long term stability: ±0.5%FS /Year
Thermal effect: <0.05%FS/°C(Zero), <0.08%FS/°C(FS)
Response time: 0.5-30s
Power: 16-28V AC/ DC, optional 85-265V AC
Weight: 340g
Approval: CE
Accessory: A-S0 is standard including 2m/5mm ID tube, 3
pairs of screws and brackets. Options are A-S1, A-S2 and
A-S7-X. They can be used for surface, panel or flush mount
and should be ordered separately. See details in Accessorie
FS(±2.0%FS@25Pa range) Long term stability: ±0.5%FS /Year
Thermal effect: <0.05%FS/°C(Zero), <0.08%FS/°C(FS)
Response time: 0.5-30s
Power: 16-28V AC/ DC, optional 85-265V AC
Weight: 340g
Approval: CE
Accessory: A-S0 is standard including 2m/5mm ID tube, 3
pairs of screws and brackets. Options are A-S1, A-S2 and
A-S7-X. They can be used for surface, panel or flush mount
and should be ordered separately. See details in Accessorie






Apply high accuracy MEMS sensor and digital technologies,
can measure positive,negative or differential pressure. It can
replace most of the traditional pointer mechanical gauges.
It combines the gauge and two relays for control function
It can measure and control system pressure of fan, blower,
filter, furnace draft and orifice plate and can apply to various
clean room, biological safety cabinet, clean bench, ducts
collection, medical or pharmaceutical machine, etc.
Suitable for surface, panel or flush mount
Multiple ranges and engineering unitsselectable
No any movable parts, no any effect onvibration
The accuracy is up to ±1% FS and the range can be 25pa
Function keys: zero calibrate, units select, relay set,etc.
Optional arch LED display for output and alarm
can measure positive,negative or differential pressure. It can
replace most of the traditional pointer mechanical gauges.
It combines the gauge and two relays for control function
It can measure and control system pressure of fan, blower,
filter, furnace draft and orifice plate and can apply to various
clean room, biological safety cabinet, clean bench, ducts
collection, medical or pharmaceutical machine, etc.
Suitable for surface, panel or flush mount
Multiple ranges and engineering unitsselectable
No any movable parts, no any effect onvibration
The accuracy is up to ±1% FS and the range can be 25pa
Function keys: zero calibrate, units select, relay set,etc.
Optional arch LED display for output and alarm
Medium: non-combustible, non-corrosive air, not sensitive to
moisture, dust, condensation and oil
Medium Temp.: 0-60°C
Materials: cast aluminum housing and PC plate
Work Environment: -20~70°C
Compensated Temp.: 0-50°C
Work pressure: 1, 2, 5 or 10Kpa for different ranges
overload 5xFS, burst 10xFS
Dimension: see diagram
Connection: 1/8” ID tubing, two pairs (on left side and back)
Display: 4 bits 0.8” red LED
Relay output: 2×SPST, 3A×30VDC/250VAC or 1×Buzzer
moisture, dust, condensation and oil
Medium Temp.: 0-60°C
Materials: cast aluminum housing and PC plate
Work Environment: -20~70°C
Compensated Temp.: 0-50°C
Work pressure: 1, 2, 5 or 10Kpa for different ranges
overload 5xFS, burst 10xFS
Dimension: see diagram
Connection: 1/8” ID tubing, two pairs (on left side and back)
Display: 4 bits 0.8” red LED
Relay output: 2×SPST, 3A×30VDC/250VAC or 1×Buzzer

Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing Ifan Peng Instrument Co., Ltd.
Location
2006, Block C, Dongsheng Plaza, Shijiazhuang, Hebei, China
Contact Person
Kayla Pan