Nanjing Kelisaike Safety Equipment Co., Ltd.
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

WT602 Laser Dust Meter Real-Time PM Monitoring For CEMS Industrial Boilers And Emission Control Systems

Price Negotiable
Price: USD 1200
MOQ: MOQ 1pc
Delivery Time: Negotiable
Product Description

WT602 Laser Dust Meter

Product Description

The WT602 Dust Meter is an independently developed and manufactured online dust monitoring system. It employs laser backscatter measurement technology with all key components imported, providing highly accurate and reliable continuous monitoring of particulate matter emissions from various pollution sources. The device can be integrated with a Continuous Emission Monitoring System (CEMS) or operate independently in single or multiple-unit networks, sharing a common data acquisition and processing platform.

The WT602 is widely applied across thermal power, steel and metallurgy, petrochemical, cement, ceramics, and waste incineration industries. It is suitable for monitoring emissions from boilers, industrial kilns, and flue gas desulfurization and dust removal systems, ensuring precise control of particulate matter emissions.

Technical Characteristics

  1. Utilizes laser backscatter technology to maintain stability, minimizing errors caused by mechanical vibrations or uneven temperature-induced refractive index changes.

  2. Supports single-side installation without the need for optical path alignment.

  3. On-site display allows direct reading of dust concentration at the monitoring location.

  4. Laser beam modulation enhances the system’s resistance to interference.

  5. Designed for tool-free installation, simplifying field setup and reducing installation complexity.

  6. Provides standard 4–20 mA industrial current output for easy system integration.

  7. Extremely low power consumption, approximately 3 W for the entire device.

  8. Standard configuration is suitable for flue walls less than 400 mm thick and stacks larger than the device label size, with customizable measurement areas adjustable under professional guidance.

 

图片7

  • TECHNICAL SPECIFICATIONS:

 

Note: has adopted a 128x64 graphic LCD for display. The LCD contrast display adjustment can be made through adjusting a potentiometer on the front panel.

 

Parameters WT602 WT602B
Principle Laser backscatter
Working wavelength 650nm
Zero drift ±2%F.S./24h ±2%F.S./24h
Range drift ±2%F.S./24h ±2%F.S./24h
Indication error ±15% ±15%
Response time ≤ 10s ≤ 10s
Diameter of flue (1-15)m (0.7-20)m
Operating temperature (-40~+65) ºC (-20+50) ºC
Flue temperature <200ºC 500ºC
Flue pressure 1Kpa -
Signal output (4-20) mA (4-20) mA
Power supply DC 24V ± 10% DC 24V ± 10%

32

Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Kelisaike Safety Equipment Co., Ltd.
Location Bldg 12, 2 Qingshuiting West Road, Nanjing, Jiangsu, China, 211102
Contact Person Lisa

Request A Quote

Please check your email address.
Your message must be at least 20 characters.