Cat5E FTP Cable 1000FT (F/UTP) — 24AWG Solid Copper, LSZH Jacket, Shielded LAN Cable For Data Centers

Price Negotiable
Price: 50$-100$
MOQ: 1000pcs
Delivery Time: 15-45Days
Brand: ITI-LINK
Product Description
Cat5E FTP Cable 1000FT (F/UTP) — 24AWG Solid Copper, LSZH Jacket, Shielded LAN Cable For Data Centers

High-performance CAT5E FTP Cable by ITI-LINK — 1000FT blue shielded LAN cable with 24AWG solid oxygen-free copper conductors, aluminum foil overall shield (F/UTP), and LSZH jacket for enhanced fire safety. Designed for stable 100MHz performance and reliable EMI protection in data centers, industrial networks, 5G sites and enterprise wiring. Compliant with ANSI/TIA-568-B.2 and ISO/IEC 11801.

Product Overview

ITI-LINK's ITI-CT5F-028 Cat5e FTP Shielded LAN Cable (1000FT) combines solid copper 24AWG conductors, foil overall shielding and LSZH jacketing to deliver a safe, shielded communication medium for commercial and industrial deployments.

Performance

Measuring to Category 5e standards (100 MHz), this shielded cable supports reliable network throughput for office & industrial networks. The F/UTP design reduces EMI susceptibility while maintaining low insertion loss across standard run lengths.

Structure & Materials

4 twisted pairs of oxygen-free copper (solid), aluminum foil overall shield, PVC/PE inner jacket, and LSZH outer sheath. Rated for typical installation and operating temperatures, the cable is built for long service life and secure shield terminations.

Application Value

Specifically recommended for environments where EMI/RFI is present — e.g., manufacturing floors, electrical rooms, elevator shafts, comms closets, security systems and data center pathways. The LSZH jacket makes it suitable for enclosed public spaces and projects with fire safety requirements.

Brand Trust

ITI-LINK guarantees quality control and compliance with industry standards and international certifications, making ITI-CT5F-028 a sensible choice for procurement and integration in professional network projects.

Specifications
Construction & Electrical Properties
Conductor Material Bare Solid Copper (elongation: 19 ~ 24%)
Conductor OD 24 AWG
Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
Resistance unbalance within a pair ≤ 2%
Insulation Material HDPE 8303
Insulation Resistance >1500 MΩ / 100m
Mutual capacitance 5600 pF / 100m MAX
Capacitance unbalance pair to ground ≤ 160 pF / 100m
Characteristic impedance at 100MHz 100 ± 15 Ω
Dielectric Strength Test Voltage 1.00KV DC or 0.7 KV AC for 1 min (no breakdown)
Jacket Material LSZH, 60P, -20~75℃
Jacket OD 5.2 ± 0.15 mm
Shield Construction Polyester/Aluminium (PET/ALU)
Shield Coverage ≥ 115%
Transmission Properties
Frequency (MHz) Attenuation (Max dB/100m) Propagation Delay (MAX ns/100m) Return Loss (Min dB) NEXT (Min dB)
1 4.05 552 45 56.27
10 6.47 545.38 25 50.3
100 21.98 537.6 20.11 35.3
Installation Notices
  1. Open the packaging, check the products carefully, and handle them gently.
  2. Please strictly follow the wiring standards during construction, and do not tie or excessively bend the network cables.
  3. When making RJ45 network cable connectors, please follow the T568B or T568A standards to ensure the correct wire sequence and avoid problems such as disconnected lines or unstable network connections.
  4. It is best to use a single network cable at a distance of no more than 100 meters to ensure optimal transmission performance.
  5. Ensure that the shielded network cable is grounded during installation.
Applications
  • Enterprise Horizontal Cabling: Office floors where shielded segments improve performance near electrical equipment.
  • Control Rooms & Substations: Environments with high EMI where FTP shielding preserves signal integrity.
  • Transportation & Railway: Use in stations, control centers and tunnels where low smoke propagation is essential.
  • Manufacturing & Automation: Connect sensors, HMIs and industrial switches requiring shielded twisted pair reliability.
  • Audit & Secure Installations: Encrypted/secure networks where additional shielding helps reduce electromagnetic leakage.
ITI-LINK Cat5E FTP Shielded LAN Cable - 1000FT spool with blue LSZH jacket

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Integrity Cable Co., Limited
Location Building B,C,H,I. No.30, The Third Industrial Area, Xiacun,No.102 Matian North Road, Gongming Office, Guangming New District, Shenzhen
Contact Person tony

Request A Quote

Please check your email address.
Your message must be at least 20 characters.