All in One Outdoor Energy Storage Battery Container With High Safety Lifepo4 Lithium Battery System
Price:
negotiable
MOQ:
1 piece
Delivery Time:
45-60 days
Brand:
1stess
Product Description
All in One Outdoor Energy Storage Battery Container With High Safety Lifepo4 Lithium Battery System
Product Features
- Plug-and-Play for ready to use
- All-in-One integrated modular design
- DC coupled for solar accessing
- Unbalanced loads operation
- Parallel operation up to 60 units
- Virtual Power Plant (VPP) enabled
- Auxiliary grid service application
- Complete certificate: CE (IEC 61000, IEC62619, IEC62477), UL, G99, UN3480, UN38.3
Technical Specifications
| Parameter | EnerArk2.0-NBN-P50 | EnerArk2.0-NBN-P100 |
|---|---|---|
| DC Side Parameters | ||
| Cell type | LFP-280Ah | |
| Module model | IP20S | |
| Battery capacity range | 143.36kWh~215kWh | 215kWh |
| AC On-Grid Side Parameters | ||
| Grid connection type | 3P4W | |
| Charging/discharging power | 50kW | 100kW |
| Rated grid voltage | AC 400V±15% | |
| Frequency range | 45Hz~55Hz | |
| Rated AC output current | 72A | 144A |
| Power factor | 0.8(Leading)~0.8(Lagging) | |
| Harmonics | ≤3%(at rated power) | |
| AC Off-Grid Side Parameters | ||
| Load type | 3P4W | |
| Rated output power | 50kW | 100kW |
| Rated output voltage | AC400V±1% | |
| Rated output frequency | 50Hz | |
| Rated current | 72A | 144A |
| Frequency accuracy | 0.2Hz | |
| General Parameters | ||
| Dimensions (W*H*D) | 1900mm*2100mm*1330mm | |
| Packing size (W*H*D) | 2100mm*2244mm*1500mm | |
| Maximum weight | 2500kg | |
| Degree of protection | IP55 (Battery Cabinet) IP34 (Electrical Cabinet) | |
| Cooling method type | Battery Cabinet (air conditioner) & Electrical Cabinet (forced air cooling) | |
| Fire fighting system | FM200 automatic fire extinguishing | |
| Anti-corrosion grade | C3 | |
| Relative humidity | 0-95% (non-condensing) | |
| Operating temperature* | -20℃~50℃ | |
| Altitude** | <2000m | |
| Noise level | ≤75dB | |
| Communication interface | RS485, Ethernet | |
| Communication protocol | Modbus RTU, Modbus TCP/IP | |
| Product standard warranty | 5 years, 6000 cycles (0.5C, 95%DOD, EOL:70%) | |
| PV Side Parameters (Optional) | ||
| Maximum PV input power | 30kW/60kW/90kW/120kW | |
| MPPT voltage range | 200V-850V | |
| Number of MPPTs | 1/1/2/2 | |
| Number of PV inputs | 1/1/2/2 | |
| Maximum input current | 100A/200A/300A/400A | |
| Certifications | CE (IEC61000, IEC62619, IEC62477), UN3480, UN38.3, MSDS Converter: UK G99, VDE4105, EN50549 Cell: IEC62619, UL1973, UL1642, UL9540A | |
* Operating temperature range
** Maximum operating altitude
** Maximum operating altitude
Product Images
Installation & Suitability FAQs for Different Countries/Regions
Singapore (Asia)
Q1: How does the system cope with Singapore's constant high heat and humidity?
A: The 50°C limit and 0-95% humidity rating are well-suited. Enhanced cooling options are available for sustained high ambient temperatures.
Q2: Is it suitable for space-constrained urban installations?
A: Yes. Its compact footprint (1.9m x 2.1m x 1.33m) and high energy density make it ideal for rooftops or parking lots.
Q3: Can it help reduce demand charges for commercial buildings?
A: Absolutely. Peak shaving and load shifting capabilities directly lower peak demand tariffs, a major cost in Singapore.
Q4: How does it handle frequent thunderstorms?
A: The system includes surge protection devices. Proper grounding as per installation manual ensures safety during storms.
Q5: Is it compliant with Singapore's grid code?
A: While not listed, the product can be tested and certified to Singapore Standards (SS) as part of the project.
Indonesia (Asia)
Q1: Can EnerArk-2.0 withstand tropical rainforest humidity and heavy rainfall?
A: Yes. IP55 and high humidity tolerance ensure performance. The cabinet's materials are chosen to resist mold and fungal growth.
Q2: Is it suitable for remote islands with weak grids?
A: Ideal. It forms stable microgrids with solar, wind, or generators, providing 24/7 power for resorts or villages.
Q3: How does it handle volcanic ash fallout?
A: IP55 protects against fine particulates. More frequent cleaning of heat exchangers and filters may be needed during ash events.
Q4: Can it support tourism resorts with high, variable loads?
A: Yes. 30-100kW output and unbalanced load operation handle fluctuating demands from hotels, pools, and restaurants.
Q5: Are local service and training available?
A: We partner with local distributors for installation, training, and after-sales support.
United Arab Emirates (Middle East)
Q1: Can the system operate in desert temperatures exceeding 50°C?
A: The maximum ambient operating temperature is 50°C. For regions where temperatures may briefly exceed this, the derating function protects the system. We recommend shaded installation or optional enhanced cooling for optimal life.
Q2: How does it handle sand and dust storms?
A: IP55 is dust-tight. Sand filters on cooling intakes and regular maintenance ensure reliability during frequent dust events.
Q3: Is it suitable for solar integration in high-insolation regions?
A: Perfectly. High MPPT range and efficiency capture maximum solar energy. It's ideal for reducing diesel consumption in off-grid sites.
Q4: Can it provide backup for critical infrastructure like data centers?
A: Yes. With < 100ms response time, it ensures uninterrupted power during grid fluctuations or outages.
Q5: Are certifications accepted by DEWA and other UAE authorities?
A: CE, IEC, and UL certifications are widely accepted. We provide support for local approval processes.