F2010-K High Speed Laser Pipe Diameter Gauge with 10KHz Frequency and 0.2-10mm Measurement Range
Price:
Negotiable
MOQ:
Negotiable
Delivery Time:
7 - 15 working Days
Brand:
Screate DALA
Product Description
High-Speed Laser Micrometer for Precision Measurement
The F-K series is a high-speed optical laser micrometer utilizing laser diffraction technology for accurate 2-axis diameter, lump, and neck measurements. With sampling frequency reaching 10KHz and no motor speed limitations, it captures comprehensive measurement data even on vibrating objects.
Ultra-Fast 0.5μs Exposure Technology
The F2010-K model features an exceptionally short 0.5 microsecond exposure time, eliminating image blur and shadows to ensure maximum measurement precision.
Versatile Control Options
The DALA F2010-K supports multiple control interfaces including computer, smartphone, and touch screen for parameter configuration and measurement data management, with customization available for specific application requirements.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | F2010-K |
| Axis | 2-axis |
| Measurement Data | Diameter, ovality, lumps and necks |
| Frequency | 10KHz/axis |
| Measurement Range | 0.2-10mm |
| Repeatability | ±0.1μm |
| Accuracy | ±(0.0005+0.01%*D)mm |
| Minimum Defect Height | 0.01mm |
| Minimum Defect Length | 0.2mm (wire speed 120m/min) 0.8mm (wire speed 500m/min) |
| Dimensions | 155×140×58mm |
| Power Supply | 24V ±10% 40VA |
| Operating Temperature | 5℃-50℃ |
| Display | LED display |
| Communication Ports | Standard: WIFI, RS485 MODBUS RTU, CAN Optional: PROFIBUS, PROFINET, EtherNet/IP, EtherCAT |
| Data Collection & Analysis | Available (optional DS14 ZT display and control system, DMS1000) |
| Out-of-Tolerance Alarm | Available |
| Transparent Mode | Available |
Notes:
(1) Repeatability measured with 100ms sliding window, φ1mm round rod at measurement center area
(2) Accuracy measured with 100ms sliding window, φ1mm round rod at measurement area
(3) Minimum defect length measured with 0ms defect measurement average time at measurable area
(4) PI feedback control is optional and must be specified when ordering
(1) Repeatability measured with 100ms sliding window, φ1mm round rod at measurement center area
(2) Accuracy measured with 100ms sliding window, φ1mm round rod at measurement area
(3) Minimum defect length measured with 0ms defect measurement average time at measurable area
(4) PI feedback control is optional and must be specified when ordering