F4010-K 4-Axis Laser Scan Micrometer 0.3mm-10mm Range with 40KHz Sampling for Medical Tubing
The F4010-K laser scan micrometer utilizes Fresnel diffraction principles to deliver stable, accurate measurements with exceptional long-term reliability. This 4-axis system minimizes binding area while providing comprehensive sampling data that accurately reflects the true dimensional characteristics of measured objects.
- Ideal for vibrating object measurement with precise actual status restoration
- Perfect for applications with strict ovality requirements
- Compatible with electric wire & cable, steel wire, enamelled copper wire, medical tubing, 3D filament, and various materials regardless of transparency
Multiple-axis configuration significantly reduces binding area, enabling more comprehensive sampling data collection and superior measurement accuracy for complex geometric profiles.
Each axis operates at 10KHz sampling frequency without motor speed limitations, capturing extensive measurement data for detailed object analysis and defect detection.
The F4010-K supports comprehensive management through computer, cellphone, and touch screen interfaces for parameter configuration, measurement data management, and system control operations.
| Parameter | Specification |
|---|---|
| Model | F4010-K |
| Axis Configuration | 4-axis |
| Measurement Data | Diameter and ovality, lump and necks |
| Frequency | 40KHz (1-Axis: 10K) |
| Measurement Range | 0.3-10mm |
| Repeatability | ±0.2μm |
| Accuracy | Diameter: ±(0.001+0.01%*D)mm Ovality: <0.5mm: ±0.004mm ≥0.5mm: ±2(0.001+0.01%*D)mm |
| Minimum Defect Height | 0.01mm |
| Minimum Defect Length | 0.2mm (wire speed 120m/min) 0.8mm (wire speed 500m/min) |
| Dimensions | 275×242×60mm |
| Power Supply | 24V ±10% 40VA |
| Operating Temperature | 5℃-50℃ |
| Display | LED display |
| Communication Ports | Standard: WIFI, RS485 MODBUS RTU, CAN Optional: PROFIBUS, PROFINET, EtherNet/IP, EtherCAT |
| Electrical Ports | Standard: digital output (relay), digital input, analog input, encoder pulse input port Optional: PI feedback control |
| Data Collection & Analysis | Available (optional DS14 ZT display and control system, DMS1000) |
| Out-of-tolerance Alarm | Available |
| Transparent Mode | Available |
(1) Set sliding window as 100ms, outside diameter repeatability of φ1mm round rod at measurement center area
(2) Set sliding window as 100ms, outside diameter deviation of φ1mm round rod at measurement area
(3) Set defect measurement average time as 0ms, the minimum defect length which cannot be missed at the measurable area
(4) PI feedback control is optional, but must be ordered when placing order
Get in Touch