Ultra-High Speed Dimensional and Defects Measurement Device with 46KHz Sampling and 0.03-120mm Range
When an object is captured by a laser beam passing through a lens, bright and dark areas form on the CCD sensor. The object's dimensions are then accurately calculated through advanced software analysis and computation algorithms.
Featuring an incredibly short exposure time, the F2010-k model excels at capturing object images without blur or shadow, ensuring precise measurement accuracy and reliable defect identification.
- Round wire, flat wire, and transparent wire measurement
- Hose and bar dimensional analysis
- Diameter, ovality, width, and thickness measurement
- Lumps and necks defect detection
| Model | TL-3006D | TL-3025D | TL-3025Q | TL-3120D |
|---|---|---|---|---|
| Axis | 2-axis | 2-axis | 4-axis | 2-axis |
| Measurement Range | 0.03-6mm | 0.2-25mm | 0.2-25mm | 0.8-120mm |
| Repeatability | ±0.03μm | ±0.1μm | ±0.1μm | ±0.3μm |
| Accuracy | ±0.5μm | ±2μm | ±2μm | ±5μm |
| Sampling Frequency | 46KHz/Axis | 46KHz/Axis | 46KHz/Axis | 20KHz/Axis |
| Size (L×W×H) | 180×198×60mm | 270×296×60mm | 380×380×68mm | 507×492×65mm |
- Power Supply: 24V ±5%, Max. 75W
- Display: LED
- Communication Interface: Standard RS485 MODBUS RTU, CAN, WIFI; Optional PROFIBUS, PROFINET, EtherNet/IP, EtherCAT
- Electrical Port: Digital output (relay), Digital input, Analog input encoder pulse input port; Optional PI feedback control, Analog output
- Working Temperature: 0-50℃
- Working Environment: 20-85% RH (No condensation)
- Brightness Tolerance: Incandescent light, fluorescent lamp 3000lx or less
- Vibrating Resistance: 10-55Hz full amplitude 1.5mm in XYZ direction for 2 hours
- Impact Resistance: 10G/6ms
- IP Grade: IP65
- DMS1000 Measurement Software System
- DS14 ZT Display and Control System
- Out-of-tolerance Alarm: Supported
- Transparent Mode: Supported
(1) Set average number of times to 1150 and measure the ±2σ value of the round standard rod of diameter 10mm at the measurement area center.
(2) For object diameter of 10mm, the measurement accuracy is ±2μm when it moves in the center of 8×8mm.
(3) PI feedback control and analog output options must be ordered when placing device order.
(4) Move φ1mm round rod in the measurement area of 2×2mm and conduct measurement error.
(5) Move φ10mm round rod in the measurement area of 8×8mm and conduct measurement error.
(6) Move φ40mm round rod in the measurement area of 40×40mm and conduct measurement error.
(7) Industrial communication module and PI feedback control module is installed before ex-factory, so notify the demand before placing an order.