Huawei CE12804S Data Center Core Enterprise Campus Switches designed with ≥ 48 Ports
Price:
$4,000.00/pieces 1-9 pieces
MOQ:
1 unit
Delivery Time:
Negotiable
Brand:
H3C
Product Description

CE12804S-DC Overview
CE12804S-DC is CE12804S DC Assembly Chassis with Fans.
Quick Specs
Figure 1 shows the appearance of CE12804S-DC.
Table 1 shows the Quick Specs.
| Product Code | CE12804S-DC |
| Switching Capacity? (Tbit/s) |
45/ 258 |
| Forwarding Rate? (Mpps) |
17,280 |
| Service Slots | 4 |
| Switching Fabric? Module Slots |
2 |
| LPU slots | 4 (slot IDs: 01 to 04) |
| MPU slots | 2 (slot IDs: 05 to 06) |
| CMU slots | None (monitoring function integrated on the MPU) |
| SFU slots | 2 (slot IDs: 07 to 08) |
| Power slots | 4 (slot IDs: PM1 to PM4) |
| Fan slots | 3 (slot IDs: FAN1 to FAN3) |
The Modules, Cards
Table 2 shows the recommended elements for the CE12804S-DC.
| Model | Description |
| AC power module | |
| PAC-2700WA | 2700W AC Power Supply |
| FE-SFP optical transceiver | |
| SFP-FE-SX-MM1310 | Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
| eSFP-FE-LX-SM1310 | Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
| S-SFP-FE-LH40-SM1310 | Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
| GE-SFP optical transceiver | |
| eSFP-GE-SX-MM850 | Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
| SFP-GE-LX-SM1310 | Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
| S-SFP-GE-LH40-SM1310 | Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
| S-SFP-GE-LH40-SM1550 | Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
| 10G-SFP+ optical transceiver | |
| SFP-10G-USR | 10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
| OMXD30000 | Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
| 40GE CFP optical transceiver | |
| CFP-40G-LR4 | High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC) |
| CFP-40G-ER4 | High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC) |
| 40GE QSFP+ optical transceiver | |
| QSFP-40G-eSR4 | 40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver) |
| QSFP-40G-ER4 | 40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
| 100GE CFP optical transceiver | |
| CFP-100G-SR10 | High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO) |
| CFP-100G-LR4 | CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC) |
| CFP-100G-ER4 | High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC) |
| GE copper transceiver | |
| SFP-1000BaseT | Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
| 100GE interface card | |
| CE-L12CF-EG | 12-Port-100GE Interface Card(EG,CFP2) |
| CE-L08CC-EC | 8-Port-100G Interface Card(EC,CXP) |
| 10GE interface card | |
| CE-L48XT-EC | Huawei 48-port 100M/1000M/10G Base-T Interface Card(EC,RJ45) CE-L48XT-EC |
| CE-L48XS-EC | 48-Port-10GE Interface Card(EC,SFP+) |
| 40GE interface card | |
| CE-L24LQ-EC1 | 24-Port-40G Interface Card(EC1,QSFP+) |
| CE-L12LQ-EF | 12-Port-40G Interface Card(EF,QSFP+) |
| Firewall module | |
| CE-FWA | Huawei CE12800 NGFW Module A CE-FWA, with HW General Security Platform Software |
| GE interface card | |
| CE-L48GT-ED | 48-Port 10/100/1000BASE-T Interface Card(ED,RJ45) |
| CE-L48GS-ED | 48-Port 100/1000BASE-X Interface Card(ED,SFP) |
Compare to Similar Items
Table 3 shows the comparison of CE12804A-B01 and CE12804S-DC.
| Product Code | CE12804S-DC | CE12804A-B01 |
| Switching Capacity? (Tbit/s) |
45/ 258 |
45/ 258 |
| Forwarding Rate? (Mpps) |
17,280 | 17,280 |
| Service Slots | 4 | 4 |
| Switching Fabric? Module Slots |
2 | 6 |
| LPU slots | 4 (slot IDs: 01 to 04) | 4 (slot IDs: 01 to 04) |
| MPU slots | 2 (slot IDs: 05 to 06) | 2 (slot IDs: 05 to 06) |
| CMU slots | None (monitoring function integrated on the MPU) | 2 (slot IDs: 07 to 08) |
| SFU slots | 2 (slot IDs: 07 to 08) | 6 (slot IDs: 09 to 14) |
| Power slots | 4 (slot IDs: PM1 to PM4) | 4 (slot IDs: PM1 to PM4) |
| Fan slots | 3 (slot IDs: FAN1 to FAN3) | 9 (slot IDs: FAN1 to FAN9) |
CE12804S-DC Specification
CE12804S-DC Specifications |
|
| Switching Capacity (Tbit/s) |
45/ 258 |
| Forwarding Rate (Mpps) |
17,280 |
| Service Slots | 4 |
| Switching Fabric Module Slots |
2 |
| Fabric Architecture | Clos architecture, cell switching, VoQ, and distributed large buffer |
| Airflow Design | Strict front-to-back |
| Device Virtualization | Virtual System (VS) |
| Cluster Switch System (CSS)2 | |
| Super Virtual Fabric (SVF)3 | |
| Network Virtualization | M-LAG |
| TRILL | |
| VxLAN routing and bridging | |
| EVPN | |
| QinQ in VXLAN | |
| VM Awareness | Agile Controller |
| Network Convergence | FCoE |
| DCBX, PFC, and ETS | |
| Data Center Interconnect | BGP-EVPN |
| Ethernet Virtual Network (EVN) for inter-DC Layer 2 network interconnections | |
| Programmability | OpenFlow |
| ENP programming | |
| OPS programming | |
| Puppet, Ansible, and OVSDB plug-ins released on open source websites | |
| Linux container for open source and customization programming | |
| Traffic Analysis | NetStream |
| Hardware-based sFlow | |
| VLAN | Adding access, trunk, and hybrid interfaces to VLANs |
| Default VLAN | |
| QinQ | |
| MUX VLAN | |
| GVRP | |
| MAC Address | Dynamic learning and aging of MAC addresses |
| Static, dynamic, and blackhole MAC address entries | |
| Packet filtering based on source MAC addresses | |
| MAC address limiting based on ports and VLANs | |
| IP Routing | IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP |
| IPv6 routing protocols, such as RIPng, OSPFv3, ISISv6, and BGP4+ | |
| IP packet fragmentation and reassembling | |
| IPv6 | IPv6 over VXLAN |
| IPv6 over IPv4 | |
| IPv6 Neighbor Discovery (ND) | |
| Path MTU Discovery (PMTU) | |
| TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6 | |
| Multicast | IGMP, PIM-SM, PIM-DM, MSDP, and MBGP |
| IGMP snooping | |
| IGMP proxy | |
| Fast leave of multicast member interfaces | |
| Multicast traffic suppression | |
| Multicast VLAN | |
| MPLS | Basic MPLS functions |
| MPLS VPN/VPLS/VPLS over GRE | |
| Reliability | Link Aggregation Control Protocol (LACP) |
| STP, RSTP, VBST, and MSTP | |
| BPDU protection, root protection, and loop protection | |
| Smart Link and multi-instance | |
| Device Link Detection Protocol (DLDP) | |
| Ethernet Ring Protection Switching (ERPS, G.8032) | |
| Hardware-based Bi-directional Forwarding Detection (BFD) | |
| VRRP, VRRP load balancing, and BFD for VRRP | |
| BFD for BGP/IS-IS/OSPF/Static route | |
| In-Service Software Upgrade (ISSU) | |
| Segment Routing (SR) | |
| QoS | Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information |
| Actions include ACL, CAR, and re-marking | |
| Queue scheduling modes such as PQ, WFQ, and PQ + WRR | |
| Congestion avoidance mechanisms, including WRED and tail drop | |
| Traffic shaping | |
| O&M | IEEE 1588v2 |
| Packet Conservation Algorithm for Internet (iPCA) | |
| Dynamic Load Balancing (DLB) | |
| Dynamic Packet Prioritization (DPP) | |
| Network-wide path detection | |
| Microsecond-level buffer detection | |
| Configuration and Maintenance |
Console, Telnet, and SSH terminals |
| Network management protocols, such as SNMPv1/v2c/v3 | |
| File upload and download through FTP and TFTP | |
| BootROM upgrade and remote upgrade | |
| Hot patches | |
| User operation logs | |
| Zero-Touch Provisioning (ZTP) | |
| Security and Management |
802.1x authentication |
| RADIUS and HWTACACS authentication for login users | |
| Command line authority control based on user levels, preventing unauthorized users from using commands | |
| Defense against MAC address attacks, broadcast storms, and heavy-traffic attacks | |
| Ping and traceroute | |
| Remote Network Monitoring (RMON) | |
| Dimensions (W x D x H, mm) |
442 x 620 x 352.8 (8U) |
| Chassis Weight (empty) | < 60 kg (132 lb) |
| Operating Voltage | AC: 90V to 290V DC: -38.4V to -72V HVDC: 240V |
| Max. Power Supply | 6,000W |
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing Yongchang Gaotai Technology Development Co., Ltd.
Location
Room 811, 8th Floor, Building 3, Courtyard 38, Linfeng Second Road, Beijing, China
Contact Person
Dong Xia