The DY050 is part of Yokogawa’s digital YEWFLO vortex flowmeter series. The "DY" stands for the digital version, and "050" refers to the 50 mm (2") pipe size. It’s widely used to measure volumetric flow rates of liquids, gases, and steam using the vortex shedding principle.
Working Principle – Vortex Shedding
The DY050 operates based on the Kármán vortex street phenomenon:
- When fluid flows past a bluff body (called a "shedder bar") inside the pipe, vortices are alternately shed from its sides.
- The frequency of vortex shedding is directly proportional to the flow velocity.
- A piezoelectric sensor or capacitive sensor detects these vortices and converts the signal into a frequency, which is then interpreted as flow rate.
Technical Specifications
|
Parameter |
Specification |
|
Size |
2 inches (50 mm) |
|
Measurable Fluids |
Liquids, gases, steam |
|
Flow Range (typical) |
~2.5 to 25 m³/h (liquid), ~15 to 150 Nm³/h (gas, air) |
|
Accuracy |
±0.75% of reading (liquid), ±1.0% (gas/steam) |
|
Repeatability |
±0.2% of reading |
|
Operating Temp |
–29°C to +250°C (standard), up to 450°C with /HT option |
|
Pressure Rating |
Depends on flange (typically ANSI 150 to 300, up to 99 bar) |
|
Process Connection |
Flange (ANSI/DIN/JIS), Wafer type available |
|
Power Supply |
24 VDC loop-powered (2-wire) or 4-wire AC/DC models |
|
Output Signal |
4–20 mA + HART, or Foundation Fieldbus |
|
Protection |
IP66/67, optional explosion-proof (Ex d) and intrinsically safe |
Optional Features (/MV, /HT, etc.)
|
Option Code |
Functionality |
|
/MV |
Built-in temperature sensor for mass flow measurement |
|
/HT |
High-temperature version for steam up to 450°C |
|
/R1, /R2 |
Reduced bore design for better low flow sensitivity |
|
/FF1 |
Foundation Fieldbus communication protocol |
|
/S2, /A2 |
Sensor material options: 316SS, Duplex SS, Hastelloy, etc. |
|
/E |
Explosion-proof Ex d housing |
Advanced Features
- Spectral Signal Processing (SSP)
- Reduces noise, increases stability, and improves signal detection.
- Ideal for low flow rates and varying conditions.
- Detects abnormal vibration, flow instability, or sensor degradation.
- Can be integrated with asset management systems (e.g., Yokogawa’s PRM).
- Calculates mass flow of saturated steam or liquids using built-in temperature measurement.
Applications
|
Industry |
Use Cases |
|
Power Plants |
Steam measurement, boiler control |
|
Oil & Gas |
Natural gas, compressed air, process fluids |
|
Chemical Processing |
Steam, cooling water, solvents |
|
HVAC/Utilities |
Chilled water, hot water, building automation |
|
Food & Beverage |
CIP fluids, utilities |
Example Model Code Breakdown
DY050-F1-SS2N-2N/HT/MV
|
Code |
Meaning |
|
DY050 |
50 mm digital YEWFLO vortex meter |
|
F1 |
Flanged body |
|
SS2N |
316SS wetted parts |
|
2N |
ANSI 300 flange |
|
/HT |
High-temperature version |
|
/MV |
Mass flow with temp compensation |