3144P Harsh Environment 4-20mA Output HART Protocol transmitter Temperature Transmitter
Price:
USD 600 1 pc
MOQ:
1 pc
Delivery Time:
7-14 days
Brand:
Rosemount
Product Description
3144P Harsh Environment 4-20mA Output HART Protocol transmitter Temperature Transmitter
Highlights — Features & Functions
Advanced Sensing & Accuracy
- Universal inputs: Accepts RTDs (2/3/4-wire), thermocouples (Types B, E, J, K, N, R, S, T, L, U, W5Re/W26Re), millivolt, and ohm signals
- Single or dual‑sensor mode: Supports differential, averaging, redundant measurement, Hot‑Backup®, and Sensor Drift Alert capabilities
- Transmitter‑Sensor Matching (C2 option): Calibrates with RTD sensor characteristics to reduce interchangeability error by ~75%
Diagnostics & Safety
- Thermocouple loop degradation detection: Monitors for changes in resistance that might indicate wire issues
- Min/max tracking: Continuously logs peak values for both process and ambient temps
- Sensor Drift Alert: Warns if dual-sensor readings diverge beyond preset thresholds
- Hot Backup® (U1 option): Seamlessly switches to backup sensor if primary fails, ensuring uninterrupted output
- IEC 61508 Safety-Certified: HART‑based units certified up to SIL 2 (1oo1 logic) and SIL 3 (redundant 1oo2 setup)
- Independent fail‑safe circuit: In case of processor failure, analog output goes to preset fail‑high or fail‑low state.
Physical & Environmental Design
- Dual‑compartment rugged housing: Offers robust protection (NEMA 4X/IP66/68) against water, dust, wiring noise, and EMI
- Enclosure materials & entries: Low‑copper aluminium or optional stainless steel, with ½‑14 NPT, M20, PG13.5, or JIS conduit options
- Operating & storage range: –40 °C to +85 °C (electronics); –60 °C to +120 °C (storage) .
- Stability specs: RTDs maintain ±0.25 % or ±0.25 °C over 5 years; thermocouples ±0.5 % or ±0.5 °C
- Self‑calibrating ADC and robust EMC performance (IEC 61000‑4‑3 up to 30 V/m test)
Communication & Local Interface
- 4‑20 mA + HART (Rev 5/7) or FOUNDATION Fieldbus (ITK 6.0, NE107) with built‑in AI, PID, and advanced diagnostics function blocks
- Local LCD display: Shows process value and diagnostics graphically; suave configuration and verification onsite
Wiring / Configuration Snapshots
- Single sensor wiring: Standard RTD or thermocouple hook-up diagrams available for HART and Fieldbus modes.
- Dual sensor wiring: Supports dual RTDs, dual T/Cs, or mixed RTD+T/C setups—ideal for ΔT, averaging, or redundant measurements
- Typical response time: ~0.5 s for single-sensor mode, ~1 s for dual sensors.
Available Options & Configurability
|
Option Code |
Feature |
|
PT |
X‑well™ pipe clamp sensor assembly |
|
C1 |
Factory data: date, tag, custom alarms |
|
C2 |
Transmitter‑sensor matching |
|
Q4 |
5‑point calibration certificate |
|
U1/U2 |
Hot Backup, averaging, drift alert modes |
|
M5 |
Local LCD display |
|
T1 |
Transient protection |
|
QT |
SIL certification |
|
HR7 |
HART revision 7 |
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Xiyi Central Control Technology Co., Ltd.
Location
Room 2204, Unit 1, No. 91, Taoyuan South Road, Xi'an, Shaanxi, China
Contact Person
Lee