Endress + Hauser Liquid Flow Parameter Proline Promag 5W3B80 Series Tantalum Electrode

Price Negotiable
Price: USD 1000
MOQ: 1 pc
Delivery Time: 7-14 days
Brand: E+H
Product Description

What is it

The Proline Promag W 300 is an electromagnetic flowmeter (magmeter) designed especially for water and wastewater applications. It’s made to be robust in harsher environments, with a transmitter that is easily accessible. One of its distinguishing features is that it offers a “0 × DN” inlet/outlet run version (i.e. no required straight lengths upstream/downstream) and a “full bore” design that avoids constrictions and associated pressure loss.

 

Key Features & Benefits

Here are the main strengths and special features:

Feature

Description / Benefit

Accuracy

The standard version gives ±0.5 % of reading plus ±1 mm/s. There's an optional “flat spec” version that improves upon that: ±0.2 % ±2 mm/s.

“0 × DN / Full bore”

This lets you install the meter directly after bends, T-fittings etc., with no need for long straight pipe runs upstream or downstream. That saves space, simplifies installation, and reduces pressure loss.

Wide range sizes and flows

It supports a large nominal diameter range (DN 25 up to DN 3000, i.e. ~1″ to 120″) and flow measurement range from about 0.5 m³/h up to 263,000 m³/h.

Temperature & liner materials

Different liner materials (hard rubber, polyurethane, PTFE) let you adapt to various media temperatures. For example, PTFE liner allows up to +90 °C in some cases.

Pressure ratings & construction

It supports up to PN 40 (Class 300 / 20K) in process pressure. Wetted parts are robust materials: electrodes in stainless steels, Alloy C22, tantalum; sensor housing materials are corrosion-protected.

Operation, diagnostics, verification

It has a compact, dual-compartment transmitter with up to 3 I/Os; backlit display with touch control; remote display option; various connectivity options (fieldbuses etc.). It uses Heartbeat Technology for verification, diagnostic tools, traceability.

Suitability for harsh / hazardous environments

Designed for water/wastewater plants, possibly submerged/underground installation; corrosion protection (per EN ISO 12944) etc. Approvals for drinking water; degree of protection up to IP68.


Technical Details (at a Glance)

Here are some representative specs:

Parameter

Typical Values

Flow measurement error (standard)

±0.5 % of rated flow + ±1 mm/s

Flow measurement error (flat spec option)

±0.2 % o.r. ±2 mm/s

Flow range

From approx. 0.5 m³/h up to 263,000 m³/h

Nominal Diameter

DN 25 to DN 3000 (≈ 1″ to 120″)

Medium temperature (depending on liner)

Hard rubber: 0 to +80 °C; Polyurethane: –20 to +50 °C; PTFE: –20 to +90 °C

Max process pressure

PN 40 / Class 300 / 20K

Wetted materials

Liners: hard rubber, polyurethane, PTFE; Electrodes: 1.4435 (316L), Alloy C22, UNS N06022, Tantalum

 

Where It’s Used

Typical applications include:

  • Municipal wastewater plants (influent/effluent, sludge lines)
  • Drinking water treatment, distribution measurement
  • Industrial water, process water, utility water flow monitoring
  • Situations where space is constrained or straight-pipe run requirements are difficult (after bends, on skid-mounted equipment etc.)

 

Things to Consider / Limitations

While very capable, there are a few considerations:

  • Liner material must be selected appropriately for medium-chemistry, temperature and wear. PTFE is more expensive but handles higher temperatures and more aggressive media.
  • Even though the “0 × DN” option reduces straight-pipe requirements, disturbed flow upstream (e.g. from pumps, valves, elbows) may still impose some challenges; though the Promag W 300 is designed to manage such disturbances better than many flowmeters.
  • Cost may be higher than more basic magmeters, especially when ordering higher accuracy, special liners, or hazardous-area approvals.
  • Installation, maintenance (though low) still requires attention: ensuring electrode cleaning etc., verifying calibration if needed.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi'an Xiyi Central Control Technology Co., Ltd.
Location Room 2204, Unit 1, No. 91, Taoyuan South Road, Xi'an, Shaanxi, China
Contact Person Lee

Request A Quote

Please check your email address.
Your message must be at least 20 characters.