Endress Hauser Solicap FTI55 FTI56 Capacitance Point Level Switch for Bulk Solids Endress Hauser Solicap FTI55
Price:
USD 900
MOQ:
1 pc
Delivery Time:
7-14 days
Brand:
E+H
Product Description
Overview – Solicap FTI55
- The Solicap FTI55 is a capacitance-based point level switch designed for solids (fine powders to coarse bulk materials).
- It belongs to the Solicap M series from Endress+Hauser.
- It is the rod version (FTI55); the rope version (for longer measuring lengths) is FTI56.
Official product page – Endress+Hauser
⚙️ Working Principle
- The FTI55 measures the capacitance change between its probe (rod electrode) and the vessel wall.
- When the bulk material covers the probe, the dielectric constant changes → the measured capacitance increases → the electronics switch state.
- Minimum detectable capacitance change (ΔC): ≥ 5 pF.
- Typical operating frequency: ~500 kHz.
- Available with fully or partially insulated probes, depending on the application.
- Includes active build-up compensation, allowing reliable operation even when material adheres to the probe surface.
Key Technical Specifications
|
Parameter |
Typical Value / Range |
|
Process temperature |
–50 °C … +180 °C |
|
Process pressure |
Vacuum … +25 bar |
|
Probe length |
200 mm … 4000 mm (≈ 8 in … 157 in) |
|
Housing materials |
Aluminum, polyester, or stainless steel |
|
Repeatability |
± 0.1 % |
|
Supply / output |
Multiple electronics versions (AC, DC, relay, PNP/NPN, etc.) |
|
Explosion protection |
Versions available with ATEX / FM / CSA approvals |
Installation and Application Tips
- Mounting guidelines
- The probe must not touch the vessel wall (electrical isolation required).
- Avoid direct installation in the filling stream (material falling directly on the sensor).
- For non-metallic silos (plastic, fiberglass), add a metal counter-electrode plate outside the wall.
- Ensure good grounding and shielding for stable capacitance measurement.
- Simple on-site calibration via push-button.
- Calibration data stored in EEPROM — retained even if electronics are replaced.
- Active compensation minimizes false switching from material deposits on the probe.
- Regular cleaning still recommended for sticky or moist products.
- Choose length according to required switching point (high level, low level, etc.).
- For low dielectric materials (εr < 2), sensitivity adjustments may be required.
- Equipped with two-stage surge and ESD protection.
- In Ex environments, always follow specific wiring and grounding rules from the certification documents.
Typical Applications
- Point level detection in:
- Silos or bins with powders, granules, or pellets
- Cement, grain, plastic pellets, feed, sand, etc.
- Works well in dusty, abrasive, or sticky media.
- Can be used for both high-level and low-level detection.
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Xiyi Central Control Technology Co., Ltd.
Location
Room 2204, Unit 1, No. 91, Taoyuan South Road, Xi'an, Shaanxi, China
Contact Person
Lee