Fuji Smart SMT Nozzle Cleaner AHC-R1 Auto Head Cleaner 2A
| Attribute | Value |
|---|---|
| TYPE | AHC-R1 |
| DESIGNATION | AUTO HEAD CLEANER |
| DRAWING NUMBER | 2RGKBM0037** |
| SUPPLY VOLTAGE | AC200V-230V |
| FULL LOAD AMP. | 2A |
| SHORT-CIRCUIT-CURRENT-RATING | 5kA rms |
| SHORT-CIRCUT-BREAKING CAPACITY | 14kA |
| FREQ | 50/60Hz |
| PHASE | 3 |
| ENCLOSURE RATING | IP22 |
Nozzle stations can be set directly after being removed from mounters. The Smart Nozzle Cleaner removes nozzles from stations, and cleans and inspects the nozzles automatically just by pushing the start button.
The Smart Nozzle Cleaner checks the conditions of all nozzles and rejects nozzles that do not pass inspection into reject boxes based on the reason for rejection.
- Reads 2D codes
- Checks air flow
- Checks nozzle sliding movement
- Checks for nozzle tip damage
Through automation, operator work time can significantly be reduced from 120 to 0.4 seconds per nozzle (excluding inspection time). In a market that often does not have enough staff, this unit greatly contributes to labor saving.
Since the Smart Nozzle Cleaner has a large storage capacity, it can be used as a nozzle stocker. Select the right type of operation for your production from the various available operation modes.
- Normal operation - Sets nozzles in a nozzle station after cleaning and inspecting the nozzles.
- Exchange operation - Exchanges the nozzles in the nozzle station that is set in the Smart Nozzle Cleaner with nozzles in the stocker which have been cleaned and inspected.
- Stocker operation - Performs cleaning and inspection for uncleaned nozzles in the stocker.
- Inspection operation - Performs inspection on nozzles in a nozzle station set in the Smart Nozzle Cleaner.
- Manual operation - Sets the specified types and quantity of nozzles in a nozzle station, or discharges the nozzles onto a tray without setting them in a nozzle station.