Lab Universal Gas Chromatograph High Resolution and Decentralized Detection
Price:
Negotiable
MOQ:
1 unit
Delivery Time:
5-8 days
Brand:
XZH TEST
Product Description
XHSP1700 Lab Universal Gas Chromatograph High Resolution and Decentralized Detection
Basic Info.
Model NO.
XHSP1700
Test Mode
Saved Test
Test Region
Forming Cable
Cable Type
CAT3
Certification
CE
Customized
Customized
Color
Black
Test Frequency
128Hz/111Hz/105Hz/94Hz(Afc)
Resolution
0.5m
Decentralized Detection
Allowed
Transport Package
Wooden Box Filled with Foam Inside
Specification
350mm*280mm*170mm
Trademark
XZH TEST
Origin
China Xi'an
HS Code
8543201000
Production Capacity
1000pieces/Year
Product Description
Main technical datas
• operating display: 5.7 inch periodic lattice Chinesize color liquid crystal (can be equipped with touch screen)
• temperature control area: 6 ways • temperature: room temperature above 5 ºC ~ 400 ºC, incremental:1 ºC, accuracy :± 0.1 ºC
• temperature-programmed order: 16 order
• Temperature program rate: 0.1 ~ 39 ºC /min (common type); 0.1 ~ 80 ºC /min (high speed)
• the gas control: optional pressure flow control mode of the mechanical valve control mode, electronic
• gas pressure, flow measurement: pointer type pressure meter or electronic pressure, flow pattern
• all electronic gas pressure, flow measurement system The single module maximum measuring way: 16 Range: 0 ~ 0.3MPa (pressure); 0 ~ 500sccm (flow) Resolution: 0.01kPa (pressure); 0.01sccm (flow)
• EPC, EFC work mode: 3kinds:constant current mode, constant voltage mode, bypass mode
• EPC, EFC working gas: 4kinds:nitrogen, air, hydrogen, helium, argon
• EPC, EFC L: 4 order EPC, EFC: pressure control range: 0 ~ 0.6MPa; flow rate of 0 ~ 100sccm or 0 ~ 500sccm (air);
• EPC, EFC control precision pressure 0.01kPa; flow rate: 0.01sccm;
• external events: 4 road, 4 road; auxiliary control output
• injector types: packed column sample, the capillary inlet, six valve gas sampling, automatic headspace sampling.
• detector number: 3 (up); FID, TCD, ECD, FPD and NPD.
• start sampling: manual, automatic optional
• communication interface: Ethernet: IEEE802.3
![Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph]()
Detector technology index
Hydrogen flame ionization detector (FID)
•The limit of detection: ≤ 1×10-11g/s (sixteen alkyl);
• baseline noise: ≤5×10-14A
• baseline drift: ≤1×10-13A/30min
• linear range:≥106
Thermal conductivity detector (TCD)
• sensitivity: S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged ,optional.)
• baseline noise: ≤ 20 μ V
• baseline drift: ≤ 30 μ V/30min
• linear range:≥104
Electron capture detector (ECD)
•The limit of detection: ≤ 1×10-13g/ml(C 666 - isooctane solution)
• baseline noise: ≤ 0.03mV
• baseline drift: ≤ 0.2mV/30min
• linear range: 103
• source: 63Ni
Flame photometric detector (FPD)
•The limit of detection: (S) ≤5×10-11g/s, (P) ≤1×10-12g/s; methyl parathion - ethanol solution)
• baseline noise: ≤ 3×10-13A
• baseline drift: ≤2×10-12A/30min
• linear range: To sulfur≥102, To P ≥103
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Location
Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
Contact Person
Serena

