Intelligent Cable Spiker XHZS506YS with LCD Voice Prompt Remote Control Dual-Shooter for Cable Safety Verification
Every year in power systems, human accidents occur due to manual sawing of wrong live cables. The XHZS506YS Intelligent Cable Spiker completely eliminates this risk. Using a remote-controlled dual-shooter system, it performs destructive verification by piercing the target cable — if the cable is electrified it will explode (confirming danger), and if dead, no reaction occurs (confirming it is safe to cut). This is the only absolute method to verify cable status before sawing.
In power cable construction, migration, and repair work, operators must first identify the target cable among many. While design records and electronic identifiers help determine which cable to work on, the final absolute confirmation requires physical verification through controlled short-circuit — and the XHZS506YS provides this with voice-guided intelligence, dual-mode operation, and complete operator isolation.
???? XHZS506YS vs XHZS506S — Intelligent vs Basic: The XHZS506YS features an LCD display showing operation content and control process, voice prompts for step-by-step guidance, Confirm (OK) and Select push-buttons for mode selection, and timing mode for automated 10-second delay puncture. The XHZS506S offers the same core dual-shooter safety with simple indicator-light operation. Choose the XHZS506YS when your team benefits from voice guidance and visual process confirmation.
1. Strictly forbidden to test without Nail driving and empty bombs — risk of needle breakage and injury.
2. Strictly forbidden to test without bullets — risk of firing pin breakage.
3. Strictly forbidden to use live ammunition and live nails, or puncture in the air — risk of injury.
4. When the cable is pierced, the shooter body must be grounded reliably.
5. The angle between the dual shooters must NOT be 120° — preferably 60°.
6. This equipment is exclusively for cable puncture. Any other use is at your own risk.
| # | Component | Function |
|---|---|---|
| 1 | Grounding | Instrument grounding point — safety protection |
| 2 | Output 1 | Connection to shooter body 1 |
| 3 | Output 2 | Connection to shooter body 2 |
| 4 | Charging Port | DC12V charging port |
| 5 | Power Switch | Turn on/off working power |
| 6 | Confirm (OK) | Operation function confirmation key |
| 7 | Select | Select working mode (Remote / Timing) |
| 8 | Power Indicator | Real-time battery level display |
| 9 | LCD Screen | Displays operation content and control process |
| Item | Qty | Description |
|---|---|---|
| Controller | 1 | Manages cable puncture action with LCD + voice prompt control |
| Shooter Body | 2 | Low-speed piston-type device for cable piercing |
| Remote Control | 1 | Dual-button (A/B) corresponding to Output 1/2 |
| Control Line | 2 | Connection between controller and shooter bodies |
| Ground Wire / Drill | 1/1 | Field grounding with drill for reliable earth connection |
| Bullets & Nails | 1 set | S1 Red (level 5) 50 rounds + PS52C8 50 nails (standard) |
| Cleaning Tools | 1 set | Screwdriver, socket, test tube brush for shooter maintenance |
| Charger | 1 | Control box AC 220V/50Hz charging cable |
| Cable Diameter | 30mm | 40mm | 50mm | 60mm | 70mm | 80mm | 90mm | 100mm |
|---|---|---|---|---|---|---|---|---|
| Nail Spec | PS27C8 | PS37C8 | PS47C8 | PS52C8 | Consult specification sheet | |||
| Color | Black | Blue | Yellow | Red | Recommended Use |
|---|---|---|---|---|---|
| Power Level | Smallest | Small | Middle | Big (Level 5) | ≤35kV: Yellow / >35kV: Red |
Standard configuration: S1 Red (power level 5) 50 rounds + PS52C8 50 nails.
Controller Operation — Two Modes:
Manual Remote Control: After installing both shooter bodies, connecting ground, and powering on the controller, press the Select button to choose "Remote Control" mode, then press Confirm (OK). Press remote control buttons A and B following the voice prompts to pierce shooter 1 and shooter 2 respectively.
Timing Automatic Mode: After installation, press Select to choose "Timing" mode, then press Confirm (OK). The controller will automatically pierce shooter 1 and shooter 2 after a 10-second delay, allowing the operator to move to a safe distance.
Important: Keep personnel and the controller as far away from the shooter bodies as possible during puncture. Manage the remote control carefully — once the control wire is connected and the switch is on, the remote can trigger puncture at any time.
XZH TEST is a professional manufacturer specializing in cable testing, identification, fault detection, and safety verification solutions for power utilities, construction teams, and industrial customers worldwide. With a comprehensive product line including intelligent cable spikers, identifiers, route tracers, and diagnostic systems, XZH TEST delivers reliable, innovative safety solutions for the most demanding professional applications.
Contact us today for a customized cable safety solution tailored to your requirements.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.