Adjustable High Voltage Pulse Generator 0-12kV HV Surge Device
Price:
Negotiable
MOQ:
1 Unit
Delivery Time:
5-8 Work days
Brand:
XZH TEST
Product Description
Adjustable High Voltage Pulse Generator 0-12kV HV Surge Device
Low Voltage Surge Generator
The XHHV512-12L low voltage pulse generator is a tie-rod portable integrated device, which is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry.
Panel Function Description
- Safety ground: The ground of the instrument shell must be reliably connected to the ground to prevent the instrument shell from being electrified .
- High-voltage ground: Also known as high-voltage tail, must be grounded reliably to prevent high-voltage leakage and discharge.
- Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably.
- Discharge button: Press to make contact with the ball gap for manual discharge (duration of each press cannot exceed 1s).
- High voltage start button: Press to start the device and generate high voltage output when the button light is on.
- High-voltage stop button: Press to cut off the high-voltage output when test is completed or an abnormality occurs.
- Over-current protection switch: Pressed position indicates over-current protection is active.
- Voltage adjustment: Turn knob clockwise to increase output voltage, counterclockwise to decrease.
- Power switch: "I gear" turns on AC 220V power, "0 gear" turns off system power.
- Fuse holder: Contains the fuse for the AC 220V power supply system.
- Power socket: AC 220V connection port.
- Time setting: Adjusts discharge time interval.
- Ammeter: Indicates current on the high voltage side.
- Voltmeter: High voltage output voltage indicating kV meter.
- High-voltage output (EMP): Connection point for high-voltage output line during impact discharge.
- High voltage output (DC): Connection point for high voltage output line during DC withstand voltage.
Technical Specifications
| Parameter | Value |
|---|---|
| Impact high voltage | 0~12kV |
| High voltage partial pressure | 2.5 level |
| Built-in capacitor | 12μF |
| Output voltage polarity | Negative polarity |
| Impact power | 250W@peak |
| Working mode | Selectable or adjustable impulse rate and Single shot |
| Length of test cable | High-voltage output line: 2m, Ground line: 3m, Power line: 1.8m |
| Minimum Output current in DC mode | 30mA at 12kV |
| Over temperature protection | 65ºC |
| Over current protection | 8mA (more than 3 seconds) |
| Power supply | AC220V±15%, 50Hz±2Hz(60Hz) |
| Ambient temperature | -20~+60ºC |
Packing List


Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Location
Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
Contact Person
Serena