Automated Surge Testing Machine for Alternator Motor Stator with 3000V Testing Voltage and 6-Loop Configuration
Price:
Negotiable
MOQ:
Negotiable
Delivery Time:
Negotiable
Product Description
Automated Surge Testing Machine for Alternator & Motor Stators
This advanced automated testing equipment performs comprehensive electrical testing on alternator and motor stators with precision and efficiency. The system handles multiple testing procedures automatically, requiring minimal operator intervention.
Key Advantages:
- Fully automated testing process with minimal manual operation
- Scalable 6-loop testing configuration (expandable)
- Easy operation and maintenance procedures
- Comprehensive multi-parameter testing capabilities
Testing Specifications & Technical Parameters
DC Resistance Testing
| Parameter | Specification |
|---|---|
| Testing Range | 0.01Ω - 1000Ω |
| Testing Loop | 6 loop (scalable) |
| Tolerance | ±0.5% |
| Testing Method | Four-point measurement with auto ambient temperature correction |
Inductance Testing (Including 3-Phase Balance)
| Parameter | Specification |
|---|---|
| Testing Range | 10mH - 500mH |
| Testing Loop | 6 loop (scalable) |
| Tolerance | ±2.5% |
| Testing Method | Four-point measurement |
Turn-to-Turn Insulation Testing
| Parameter | Specification |
|---|---|
| Pulse High Voltage | 100V - 3000V (100V/step) |
| Pulse Peak | 0.5msec |
| Sampling Frequency | 1-40 MHz |
| Testing Loop | 6 loop (scalable) |
| Tolerance | ±2.5% |
| Judging Method | Area difference judgment (sensitive to inductance and energy loss) |
| Waveform Display | Standard (White), OK (Green), NG (Red) |
Insulation Resistance Testing
| Parameter | Specification |
|---|---|
| Voltage | DC 500V / 1000V |
| Testing Time | 1-10s (adjustable) |
| Judging Range | 1-1000 MΩ |
| Tolerance | ±2.5% |
Interphase Insulation Testing
| Parameter | Specification |
|---|---|
| Voltage | DC 500V / 1000V |
| Testing Time | 1-10s (adjustable) |
| Judging Range | 1-1000 MΩ |
| Tolerance | ±2.5% |
Interphase Hipot Testing
| Parameter | Specification |
|---|---|
| Voltage | AC 100-3000V (100V/step) |
| Testing Time | 1-10s (adjustable) |
| Judging Range | 0.1 mA - 20 mA |
| Tolerance | ±2.5% |
Hipot Testing (with Arc Detection)
| Parameter | Specification |
|---|---|
| Voltage | AC 100-3000V (100V/step) |
| Testing Time | 1-10s (adjustable) |
| Judging Range | 0.1 mA - 20 mA |
| Tolerance | ±2.5% |
Resistance Balance Testing
| Parameter | Specification |
|---|---|
| Test Method | DC resistance sampling |
| Testing Time | 0.1s |
| Judging Method | Percentage method to judge DC resistance difference between windings |