3HX Series 3 Phase Over the Side Three-Element PTFE Immersion Heaters

PTFE HEATERS:

Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters. Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

 

Excellent chemical resistance to aggressive acids.

PTFE Immersion Heater For Corrosive Chemical Heating FEATURES

· PTFE sleeved 304 stainless elements inert to most solutions up to 212°F (100°C).

· Low watt density design 10 watts/square inch (1.5w/cm²).

· Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit.

· Grounded internal metal element and built in thermal protector. Replaceable P1 protector standard for solutions up to 180°F(82°C).

· Certification: ISO9001,CE

SPECIFICATIONS

· 500 - 9000 watts

· 120 to 600 volts (600 volts on 4500 watts or lower only)

OPTIONS AVAILABLE (CONSULT FACTORY)

· Resettable thermal protectors

· Polypropylene guards (sold separately)

· Custom configurations and lengths

· Custom wire and conduit lengths

 

Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters.

Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

 

 

Others Applications

 

Point Of Use Heating
Point of Use (POU) Heating refers to the energy-efficient heating method of placing a small heater near the processing bath to reduce heat-up wait times.

 

Products For Point Of Use Heating

Applications

  • Semiconductor Wafer Cleaning

  • Etching

  • Inline Chemical Heating

  • Point of Use Heating (POU)

High-Purity PFA Inline Chemical Heater

2KW, 4KW, 6KW, 12KW, 18KW Inline Chemical Heater PFA In-Line Heater 0

PTFE Inline Heater

 

2KW, 4KW, 6KW, 12KW, 18KW Inline Chemical Heater PFA In-Line Heater 1

Inline Chemical Heater

 

2KW, 4KW, 6KW, 12KW, 18KW Inline Chemical Heater PFA In-Line Heater 2

 

RO/DI Water Heating
Deionized water (DI Water) has become a crucial part of many industrial process applications' impurity removal process. Cleaning semiconductors or other ultra-clean end-use devices requires the highest level of purity to reduce product failure.

 

Products For RO/DI Water Heating

 

Applications

  • Semiconductor

  • Flat Panel Display

Heating Systems for Purified, DI Water

PFA-jacketed Heating Element 6.3KW Inline Chemical Heater For Semiconductor 0

PTFE Inline Chemical Heater

PFA-jacketed Heating Element 6.3KW Inline Chemical Heater For Semiconductor 1

 

 

Electro-Polishing
Electro-polishing (Electropolishing) involves using electricity and chemical reactions to remove ions from the surface to deburr and reduce the surface roughness for a smooth, level, and clean surface, free of irregularities. Surplus power supplies deliver full power supply output performance, high efficiency, high-speed, DC output, connectivity, reliability, and ETL certification.

 

Products For Electro-Polishing

9HX SERIES
Low watt density, 9 element fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. Three phase. 3000-18000 watts, 208-600 volts.
10kW PTFE Inline Chemical Heater 6
6HX SERIES
Low watt density, 6 element fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. Three phase. 2000-12000 watts, 208-600 volts.
10kW PTFE Inline Chemical Heater 7

3HXOL SERIES

Low watt density, 3 element, bottom heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions . 3000-18000 watts, 208-480 volts.

10kW PTFE Inline Chemical Heater 8

 

 

 

HXF SERIES
Low-watt density, spiral heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. 500-6000 watts, 120-600 Volts.
10kW PTFE Inline Chemical Heater 12
HX SERIES
Low watt density, spiral. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions . Single phase. 500-9000 watts, 120-600 volts.

10kW PTFE Inline Chemical Heater 13

3HX SERIES
Low watt density, 3 element heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. Three phase. 1000-6000 watts, 120-600 volts.

Performs Unmatched Semiconductor Process Fluid Heating Inline Chemical Heater 11

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Yingxi Trading Company
Location Room 303, Unit 2, Building 22, Pingchou District 1, Jiangdong Street, Yiwu City, Jinhua City,Zhejiang Province,China
Contact Person Doris Lu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.