Modern Hospital School Biological Safety Cabinet with HEPA Filter Efficiency 0.12

Price Negotiable
Price: $2,000.00/pieces 2-9 pieces
MOQ: 2 pieces
Delivery Time: Negotiable
Brand: BSC
Product Description

Modern Design Class II Biological Safety Cabinet for Hospital Laboratory Furniture Workshop Pharmaceutical Home Office

Biological Safety Cabinets (BSC), are also referred to as biosafety cabinets, microbiological safety cabinets, or tissue culture hoods. BSCs provide operator, product, and environmental protection from hazardous particulates. Xunling biosafety cabinets use High-Efficiency Particulate Air (HEPA) filters and Ultra-Low Particulate Air (ULPA) filters in the exhaust and supply systems. HEPA filters remove the Most Penetrating Particle Size (MPPS) of approximately 0.3 µm
with a minimum efficiency of 99.99%, while ULPA filters remove particles of average size 0.1–0.2 µm with a minimum efficiency of 99.999%.

We produce class II biological safety cabinets, including class II Type A2 and class II Type B2. In the A2 cabinet, about 70% of air from the positive plenum is recirculated as downflow, and the remaining 30% is discharged to the lab through the exhaust filter. The Class II Type B2 biosafety cabinets are total-exhaust cabinets, no air is recirculated within them. Compared with Type A2 cabinets, Type B2 Biological Safety Cabinets have a higher class of safety protection, 0% air restriction, and 100% air exhaust. So type B2 cabinets are more often used with volatile toxic, chemicals and radionuclides, etc. Our biosafety cabinet conforms to EN12469 and NSF49.
Specification
Product name
Class II Biological Safety Cabinet
Model / Sizes
BSC-1000IIA2 / BSC-1000IIB2
Overal: 1165*760*2200 mm 
Workspace: 1000*520*640 mm

BSC-1300IIA2 / BSC-1000IIB2
Overal: 1465*760*2200 mm
Workspace : 1300*520*640 mm

BSC-1600IIA2 / BSC-1000IIB2
Overal: 1765*760*2200 mm  
Workspace : 1600*520*640 mm
Cleanliness grade
HEPA: ISO level 5 (Class 100 of 100) / ULPA: ISO level 4 (class 10 of 10)
Type
Laboratory Furniture
Filter level / efficiency
HEPA:≥99.995%,@0.3μm/ULPA:≥99.999%,@0.12μm
Application
Hospital, School, laboratory
Descent wind speed
0.33m/s
Suction air speed
0.53m/s
Vibration half peak
≤5μm
Power / maximum power consumption
AC 220V/50HZ / 1KW
Model Number
BSC1000
Wind direction
Top out
Biosafety personnel protection
CFU of all impact samplers ≤ 10, CFU of slit samplers ≤ 5
Product protection
CFU of all sampling dishes ≤ 5
Cross contamination protection
CFU of all culture dishes ≤ 2
MOQ
1 Set
Packing
Plywood Case
HEPA Filter
≥99.9995%,@0.3μm
ULPA Filter
≥99.999%,@0.12μm
illumination
≥900LX
Packing & Delivery
Plywood wooden cases,1pc/safety carton.Shanghai / Shenzhen port
FAQ
1. who are we?
We are based in Shaanxi, China, start from 2014,sell to Domestic Market(65.00%),Southeast Asia(8.00%),North America(7.00%),Eastern Europe(5.00%),Northern Europe(5.00%),Eastern Asia(3.00%),Southern Europe(2.00%),Oceania(2.00%),Western Europe(2.00%),Mid East(1.00%). There are total about 11-50 people in our office.

2. how can we guarantee quality of Class II Biological Safety Cabinet?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
Fume Hood,Chemicals Storage Cabinet,PCR Cabinet,Flexible Arm Hood, Biological Cabinet, Filtered Storage Cabinet

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xi 'an Xunling Electronic Technology Co., Ltd
Location 301, Unit 1, Building 6, Block 105, No. 38 Xianning Middle Road, Xi'an, Shaanxi, China
Contact Person Zhou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.