TMT272A Universal input field mounted temperature transmitter 4 to 20mA
Price:
Negotiable
MOQ:
10PCS
Delivery Time:
5-8 workdays
Brand:
SENSE
Product Description
TMT272A Universal input field mounted temperature transmitter 4 to 20mA
- Filed mounted HART temperature transmitter TMT2A72 for resistance
- With LCD display
- thermometers(RTD),thermocouples(TC), resistance and voltage
- transmitters,settable via HART-protocol
- High performance, high reliability
- Variety of sensor inputs
- Hart Digital communication
- Self-diagnostics function
Performance
- Temperature transmitter withHART- protocol for converting various input signals into a scalable 4 to 20 mA analogue output signal
Input
- Resistance thermometer (RTD)
- Thermocouple (TC)
- Resistance transmitter (Ω)
- Voltage transmitter (mV)
Performance
- Universal settings with HART-protocol for various input signals
- 2 wire technology, 4 to 20mA analogue output
- High accuracy in total ambient temperature range
- Galvanic isolation 2000V AC
- An internal temperature sensor for active temperature
- compensation(For T/C)
- Wide voltage supply range
- Customer speciϐic measurement range settings
- Expanded resistance input (max. 2KΩ)
- Expanded voltage input (max. 2KmV)
SENSE INSTRUMENTS has been developing and manufacturing temperature transmitters for 30 years. Our research and development team has rich experience, all products can provide PC side debugging software. And we can customize software to customers, OEM customization service is our strength. HART temperature transmitter can provide DD file, product support handheld communicator debugging.
Special Services:
- Free PC software (software can customize LOGO)
- Labels can be customized
| Input | Type | Measurement Ranges | Min.meas.ranges |
| Resistance thermonmeter(RTD) | PT100 | -200℃ to 850℃(-328℉ to 1562℉) | 10K |
| Resistance thermonmeter(RTD) | PT500 |
►-200℃ to 250℃(-328℉ to 482℉) |
10K |
| Resistance thermonmeter(RTD) | PT1000 | -200℃ to 250℃(-328℉ to 482℉) | 10K |
| Resistance thermonmeter(RTD) | Cu50 | ►-50℃ to 150℃(-58℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Cu100 | ►-50℃ to 150℃(-58℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Ni100 | ►-60℃ to 180℃(-76℉ to 356℉) | 10K |
| Resistance thermonmeter(RTD) | Ni500 | ►-60℃ to 180℃(-76℉ to 356℉) | 10K |
| Resistance thermonmeter(RTD) | Ni1000 | ►-60℃ to 150℃(-76℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Resistance(Ω) | 0Ω to 400Ω | 10Ω |
| Resistance thermonmeter(RTD) | Resistance(Ω) | 0Ω to 2000Ω | 20Ω |
| Connection type: 2-wire, 3wire, 4wire connection | |||
| Thermocouples (TC) |
B(PtR30-PtRh6) | 0℃ to 180℃(-32℉ to 3308℉) | 500K |
| Thermocouples (TC) |
E(NiCr-CuNi) | -270℃ to 1000℃(-454℉ to 1832℉) | 50K |
| Thermocouples (TC) |
J(Fe-CuNi) | -210℃ to 1200℃(-346℉ to 2192℉) | 50K |
| Thermocouples (TC) |
K(NiCr-Ni) | -270℃ to 1372℃(-454℉ to 2501℉) | 50K |
| Thermocouples (TC) |
N(NiCrSi-NiSi) | -270℃ to 1300℃(-346℉ to 2372℉) | 50K |
| Thermocouples (TC) |
R(PtRh13-Pt) | -50℃ to 1768℃(-58℉ to 3214.4℉) | 500K |
| Thermocouples (TC) |
S(PtRh10-Pt) | -50℃ to 1768℃(-58℉ to 3214.4℉) | 500K |
| Thermocouples (TC) |
T(Cu-CuNi) | -270℃ to 400℃(-454℉ to 752℉) | 50K |
| Voltage transmitters(mV) | Millivolt transmitter(mV) | -75mV to 75V | 5mV |
| Voltage transmitters(mV) | Millivolt transmitter(mV) | -700mV to 200V | 20mV |
| ► ON Request | |||
Ordering code
| Certification | |||||||
| A B |
Version for non hazardous areas NEPSI Ex ia CT4 |
||||||
| Configuration transmitter connection | |||||||
|
A
|
Standard factory configuration 3-wire | ||||||
| Configuration Configuration Configuration Configuration |
connection TC connection RTD(2-wire) connection RTD(3-wire) connection RTD(4-wire) |
||||||
| Configuration temperature sensor | |||||||
| A 1 2 3 4 5 6 7 8 B E J K N R S T |
Standard factory configuration Pt100 Pt100-200℃ to 850℃(-328°Fto 1562°F) Pt500-200℃ to 250℃(-328°F to 482"F) Pt500-200℃ to 250℃(-328F to 482°F) Pt1000-200℃ to 250℃(-328°F to 482°F) Cu50 -50℃ to 150℃(-58°F to 302°F) Cu100-50℃ to 150℃(-58°F to 302°F) Ni100-60℃ to 180℃ (-76°Fto 356°F) Ni500-60℃ to 180℃(-76°Fto 356°F) Type B 0℃ to 1820℃(-32°F to 3308°F Type E -270℃ to 1000℃(-454F to 1832°F) Type J-210℃ to 1200℃(-346°Fto 2192°F) Type K-270℃ to 1372℃(-454°F to 2501F) Type N -270℃ to 1300℃(-454°F to 2372°F) Type R -50℃ to 1768℃(-58°F to 3214.4°F) Type S-50℃ to 1768℃(-58°Fto 3214.4°F) Type T -270℃ to 400℃(-454°F to 752°F) |
||||||
| Configuration | |||||||
| A B C D |
Standard factory configuration(Pt100/3-wire/0 to 100℃) Customised measurement range Customised expanded configuration for TC Customised expanded configuration for RTD |
||||||
| TMT272A | Order code(complete) For example:TMT272A-AAAA | ||||||