HART® 7 temperature transmitter TMT192C head mounted temperature transmitter with DD files
The TMT192C head-mounted temperature transmitter is designed for use with resistance thermometers (RTD) and thermocouples (TC), as well as resistance and voltage transmitters. It offers configuration through the HART protocol, ensuring high performance and reliability. This device supports a wide range of sensor inputs, features HART digital communication, and includes a self-diagnostic function.
Application areas
- Head mounted temperature transmitter for converting various input signals into a scalable 4 to 20 mA analogue output signal
Service
- Free PC software (software can customize LOGO)
- Provide DD file
- Labels can be customized
- Packaging:
- Carton packing, 12PCS/ box
Performance
- The device offers universal configuration options for a variety of input signals and utilizes 2-wire technology with a 4 to 20 mA analog output. It ensures high accuracy across the entire ambient temperature range and features galvanic isolation. Additionally, it includes an internal temperature sensor for active temperature compensation (specifically for thermocouples). The unit supports a wide voltage supply range and allows for customer-specific measurement range settings. It also accommodates expanded resistance input up to 2 kΩ and expanded voltage input up to 2 mV
Input
- Resistance thermometer (RTD)
- Thermocouple (TC)
- Resistance transmitter (Ω)
- Voltage transmitter (mV)
| Input | Type | Measurement Ranges | Min.meas.ranges |
| Resistance thermonmeter(RTD) | PT100 | -200℃ to 850℃(-328℉ to 1562℉) | 10K |
| Resistance thermonmeter(RTD) | PT500 |
►-200℃ to 250℃(-328℉ to 482℉) |
10K |
| Resistance thermonmeter(RTD) | PT1000 | -200℃ to 250℃(-328℉ to 482℉) | 10K |
| Resistance thermonmeter(RTD) | Cu50 | ►-50℃ to 150℃(-58℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Cu100 | ►-50℃ to 150℃(-58℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Ni100 | ►-60℃ to 180℃(-76℉ to 356℉) | 10K |
| Resistance thermonmeter(RTD) | Ni500 | ►-60℃ to 180℃(-76℉ to 356℉) | 10K |
| Resistance thermonmeter(RTD) | Ni1000 | ►-60℃ to 150℃(-76℉ to 302℉) | 10K |
| Resistance thermonmeter(RTD) | Resistance(Ω) | 0Ω to 400Ω | 10Ω |
| Resistance thermonmeter(RTD) | Resistance(Ω) | 0Ω to 2000Ω | 20Ω |
| Connection type: 2-wire, 3wire, 4wire connection | |||
| Thermocouples (TC) |
B(PtR30-PtRh6) | 0℃ to 180℃(-32℉ to 3308℉) | 500K |
| Thermocouples (TC) |
E(NiCr-CuNi) | -270℃ to 1000℃(-454℉ to 1832℉) | 50K |
| Thermocouples (TC) |
J(Fe-CuNi) | -210℃ to 1200℃(-346℉ to 2192℉) | 50K |
| Thermocouples (TC) |
K(NiCr-Ni) | -270℃ to 1372℃(-454℉ to 2501℉) | 50K |
| Thermocouples (TC) |
N(NiCrSi-NiSi) | -270℃ to 1300℃(-346℉ to 2372℉) | 50K |
| Thermocouples (TC) |
R(PtRh13-Pt) | -50℃ to 1768℃(-58℉ to 3214.4℉) | 500K |
| Thermocouples (TC) |
S(PtRh10-Pt) | -50℃ to 1768℃(-58℉ to 3214.4℉) | 500K |
| Thermocouples (TC) |
T(Cu-CuNi) | -270℃ to 400℃(-454℉ to 752℉) | 50K |
| Voltage transmitters(mV) | Millivolt transmitter(mV) | -75mV to 75V | 5mV |
| Voltage transmitters(mV) | Millivolt transmitter(mV) | -700mV to 200V | 20mV |
| ► ON Request | |||
Ordering code
| Certification | |||||||
| A B |
Version for non hazardous areas NEPSI Ex ia CT4 |
||||||
| Configuration transmitter connection | |||||||
| A 1 2 3 4 |
Standard factory configuration 3-wire | ||||||
| Configuration Configuration Configuration Configuration |
connection TC connection RTD(2-wire) connection RTD(3-wire) connection RTD(4-wire) |
||||||
| Configuration temperature sensor | |||||||
| A 1 2 3 4 5 6 7 8 B E J K N R S T |
Standard factory configuration Pt100 Pt100-200℃ to 850℃(-328°Fto 1562°F) Pt500-200℃ to 250℃(-328°F to 482"F) Pt500-200℃ to 250℃(-328F to 482°F) Pt1000-200℃ to 250℃(-328°F to 482°F) Cu50 -50℃ to 150℃(-58°F to 302°F) Cu100-50℃ to 150℃(-58°F to 302°F) Ni100-60℃ to 180℃ (-76°Fto 356°F) Ni500-60℃ to 180℃(-76°Fto 356°F) Type B 0℃ to 1820℃(-32°F to 3308°F Type E -270℃ to 1000℃(-454F to 1832°F) Type J-210℃ to 1200℃(-346°Fto 2192°F) Type K-270℃ to 1372℃(-454°F to 2501F) Type N -270℃ to 1300℃(-454°F to 2372°F) Type R -50℃ to 1768℃(-58°F to 3214.4°F) Type S-50℃ to 1768℃(-58°Fto 3214.4°F) Type T -270℃ to 400℃(-454°F to 752°F) |
||||||
| Configuration | |||||||
| A B C D |
Standard factory configuration(Pt100/3-wire/0 to 100℃) Customised measurement range Customised expanded configuration for TC Customised expanded configuration for RTD |
||||||
| TMT192C | Order code(complete) For example:TMT192CA-AAAA | ||||||