SENSE Instruments Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

HART Head Mounted Temperature Transmitter TMT192C With DD Files

Price Negotiable
Price: Negotiate
MOQ: 10PCS
Delivery Time: 5-8 workdays
Brand: SENSE
Product Description

HART® 7 temperature transmitter TMT192C head mounted temperature transmitter with DD files

 

The TMT192C head-mounted temperature transmitter is designed for use with resistance thermometers (RTD) and thermocouples (TC), as well as resistance and voltage transmitters. It offers configuration through the HART protocol, ensuring high performance and reliability. This device supports a wide range of sensor inputs, features HART digital communication, and includes a self-diagnostic function.

 

 

Application areas
  • Head mounted temperature transmitter for converting various input signals into a scalable 4 to 20 mA analogue output signal
     
Service

 

  • Free PC software (software can customize LOGO)
  • Provide DD file
  • Labels can be customized
  • Packaging:
  • Carton packing, 12PCS/ box
 
Performance
  • The device offers universal configuration options for a variety of input signals and utilizes 2-wire technology with a 4 to 20 mA analog output. It ensures high accuracy across the entire ambient temperature range and features galvanic isolation. Additionally, it includes an internal temperature sensor for active temperature compensation (specifically for thermocouples). The unit supports a wide voltage supply range and allows for customer-specific measurement range settings. It also accommodates expanded resistance input up to 2 kΩ and expanded voltage input up to 2 mV

 

Input
  • Resistance thermometer (RTD)
  • Thermocouple (TC)
  • Resistance transmitter (Ω)
  • Voltage transmitter (mV)
Input Type Measurement Ranges Min.meas.ranges
Resistance thermonmeter(RTD) PT100 -200℃ to 850℃(-328℉ to 1562℉) 10K
Resistance thermonmeter(RTD) PT500

►-200℃ to 250℃(-328℉ to 482℉) 

10K
Resistance thermonmeter(RTD) PT1000 -200℃ to 250℃(-328℉ to 482℉) 10K
Resistance thermonmeter(RTD) Cu50 ►-50℃ to 150℃(-58℉ to 302℉) 10K
Resistance thermonmeter(RTD) Cu100 ►-50℃ to 150℃(-58℉ to 302℉) 10K
Resistance thermonmeter(RTD) Ni100 ►-60℃ to 180℃(-76℉ to 356℉) 10K
Resistance thermonmeter(RTD) Ni500 ►-60℃ to 180℃(-76℉ to 356℉) 10K
Resistance thermonmeter(RTD) Ni1000 ►-60℃ to 150℃(-76℉ to 302℉) 10K
Resistance thermonmeter(RTD) Resistance(Ω) 0Ω to 400Ω 10Ω
Resistance thermonmeter(RTD) Resistance(Ω) 0Ω to 2000Ω 20Ω
 Connection type: 2-wire, 3wire, 4wire connection
Thermocouples
(TC)
B(PtR30-PtRh6) 0℃ to 180℃(-32℉ to 3308℉) 500K
Thermocouples
(TC)
E(NiCr-CuNi) -270℃ to 1000℃(-454℉ to 1832℉) 50K
Thermocouples
(TC)
J(Fe-CuNi) -210℃ to 1200℃(-346℉ to 2192℉) 50K
Thermocouples
(TC)
K(NiCr-Ni) -270℃ to 1372℃(-454℉ to 2501℉) 50K
Thermocouples
(TC)
N(NiCrSi-NiSi) -270℃ to 1300℃(-346℉ to 2372℉) 50K
Thermocouples
(TC)
R(PtRh13-Pt) -50℃ to 1768℃(-58℉ to 3214.4℉) 500K
Thermocouples
(TC)
S(PtRh10-Pt) -50℃ to 1768℃(-58℉ to 3214.4℉) 500K
Thermocouples
(TC)
T(Cu-CuNi) -270℃ to 400℃(-454℉ to 752℉) 50K
Voltage transmitters(mV) Millivolt transmitter(mV) -75mV to 75V 5mV
Voltage transmitters(mV) Millivolt transmitter(mV) -700mV to 200V 20mV
► ON Request

 

 

Ordering code

    Certification
    A
B
Version for non hazardous areas
NEPSI Ex ia CT4
      Configuration transmitter connection
      A
1
2
3
4
Standard factory configuration 3-wire
Configuration
Configuration
Configuration
Configuration
connection TC
connection RTD(2-wire)
connection RTD(3-wire)
connection RTD(4-wire)
        Configuration temperature sensor
        A
1
2
3
4
5
6
7
8
B
E
J
K
N
R
S
T
Standard factory configuration Pt100
Pt100-200℃ to 850℃(-328°Fto 1562°F)
Pt500-200℃ to 250℃(-328°F to 482"F)
Pt500-200℃ to 250℃(-328F to 482°F)
Pt1000-200℃ to 250℃(-328°F to 482°F)
Cu50 -50℃ to 150℃(-58°F to 302°F)
Cu100-50℃ to 150℃(-58°F to 302°F)
Ni100-60℃ to 180℃ (-76°Fto 356°F)
Ni500-60℃ to 180℃(-76°Fto 356°F)
Type B 0℃ to 1820℃(-32°F to 3308°F
Type E -270℃ to 1000℃(-454F to 1832°F)
Type J-210℃ to 1200℃(-346°Fto 2192°F)
Type K-270℃ to 1372℃(-454°F to 2501F)
Type N -270℃ to 1300℃(-454°F to 2372°F)
Type R -50℃ to 1768℃(-58°F to 3214.4°F)
Type S-50℃ to 1768℃(-58°Fto 3214.4°F)
Type T -270℃ to 400℃(-454°F to 752°F)
          Configuration
A
B
C
D
Standard factory configuration(Pt100/3-wire/0 to 100℃)
Customised measurement range
Customised expanded configuration for TC
Customised expanded configuration for RTD
TMT192C           Order code(complete) For example:TMT192CA-AAAA

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 



 

How to programme

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SENSE Instruments Co., Ltd.
Location NO.34,885# Jinyu RD.Jinqiao
Contact Person Zhou Manhong

Request A Quote

Please check your email address.
Your message must be at least 20 characters.