Compressed Air Filter for Removal Odor
Price:
Negotiable
MOQ:
50pcs
Delivery Time:
3-7working days
Brand:
Yuka
Product Description
Product Description
Product Selling Point
① 7 Layers for Filter Element, fiber glass material, PF/AO/AA/AX with 4000-6000 hours spanlife. ② Meet the standard of ISO8573.1-2010Effectively filter solid particles up to 0.01 microns, suspended oil up to 0.001mg/m³. ③ 15 years warranty for air filter case, integrate die-casting technology with aluminum alloy material.
7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
| PF | AO | AA | AX | ACS | AR | AAR |
| As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the Compressed Air Filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
| Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
| Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
| Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
| Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
| Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
1. Aluminum Alloy material, 15 years serve life for filter housing under working condition from temperature 1.5ºC~80ºC.
Maxi. Pressure is 1.0Mpa.
2. 6000~8000 hours serve life for filter element,filtering performance up to 99%
3. Integrated die-casting filter up to 4 inch, flow rate up to 48m³/min.
4. Top cap of filter element with diversion fins, which will let the air come inside the filter more smooth, less pressure loss.
3. Integrated die-casting filter up to 4 inch, flow rate up to 48m³/min.
4. Top cap of filter element with diversion fins, which will let the air come inside the filter more smooth, less pressure loss.
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
| Model | Pipe size | Flow rates | Dimension (mm) | |||||||
| L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
| YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
| YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
| YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
| YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
| YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
| YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
| YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
| YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
| YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
| YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
| YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
| YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
| YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
| YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
| YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
| Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. | |||||||||
| Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |