Boiler Feed High Head Low Flow High Speed Centrifugal Pump

Boiler feed water service is a textbook low-flow, high-head application. The pump must overcome drum pressure plus piping losses while delivering only a modest flow, so a machine that stays efficient far from its best efficiency point is essential. This high head low flow duty is precisely what an integrally geared pump is designed for.

Rated at 442 m TDH, this boiler feed centrifugal pump is engineered as an API 610 OH6 vertical unit. The precision gearbox raises speed to deliver the head at low flow, and a low-NPSHr impeller protects the pump against the cavitation risk that comes with hot BFW.

The vertical design keeps the suction nozzle low, maximizing available NPSH and simplifying feed line routing. A tandem seal with a Plan 32 flush manages the temperature and ensures clean liquid at the seal faces even in hot, high pressure service.

Produced under ISO 9001 control, each unit is dynamically balanced, hydro-tested and performance-verified on a calibrated rig. Full documentation is issued with every pump, giving power and process plants confidence in continuity of feed water supply.

Technical Specifications
ParameterSpecification
ConfigurationAPI 610 OH6 vertical integrally geared
Maximum Flow57 m3/hr (250 gpm)
Differential Head442 m TDH (1,450 ft)
Maximum Motor Power200 kW (270 HP)
Max Case Working Pressure10.0 MPa (1,450 psi)
Operating TemperatureUp to +200 C
SpeedUp to 23,000 rpm
Seal OptionsTandem with API Plan 32 flush
Flange Rating600# / 900# ANSI RF and RTJ
MountingVertical
Materials of Construction
ComponentMaterial of Construction
Pump CaseCarbon Steel or 316 SS
Impeller and Inducer316 SS
Shaft17-4PH
Seal FacesSilicon Carbide / Tungsten Carbide
GasketsGraphite on SS spiral wound
Key Advantages
  • High head low flow design: efficient at the duty point many boilers require.
  • Low NPSHr impeller: protects against cavitation in hot feed water.
  • Vertical suction-near-floor layout: maximizes available NPSH.
  • Plan 32 flush seal: keeps seal faces clean and cool.
  • ISO 9001 build: verified performance and full documentation.
Typical Applications
  • Boiler feed water service
  • High head low flow process duty
  • Power and process plant utilities
  • Hot liquid pressure boosting
Frequently Asked Questions
Q: Why is the TDH so high with low flow?
A: Boiler feed must overcome drum pressure plus line losses at modest flow; an integrally geared pump delivers that high head efficiently.
Q: How is cavitation prevented?
A: A low-NPSHr inducer and a vertical suction-near-floor layout maximize available NPSH in hot feed water.
Q: What seal arrangement is used?
A: A tandem seal with an API Plan 32 clean water flush keeps the seal faces cool and clean.
Q: Can it match my boiler duty point?
A: Yes. Provide flow, TDH, temperature and fluid; our engineers will confirm the trim and provide a quote.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Sunstrand Fluid Handling Co., Ltd.(China)
Location 515 Hualian Road, Lingxi Town, Cangnan County, Wenzhou City, Zhejiang Province
Contact Person David Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.