MTL5514 MTL Switch Proximity Detector Interface 10ms

Price Negotiable
Price: Negotiate
MOQ: 1
Delivery Time: stock
Brand: MTL
Product Description

MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum

 

The MTLx514 enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults
are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection

 

 

  • Number of channels

    One

  • Location of switch

    Zone 0, IIC, T6 hazardous area

    Div.1, Group A, hazardous location

  • Location of proximity detector

    Zone 0, IIC, T4–6 hazardous area, if suitably certified

    Div.1, Group A, hazardous location

  • Hazardous–area inputs

    Inputs conforming to BS EN60947–5–6:2001 standards for

    proximity detectors (NAMUR)

  • Voltage applied to sensor

    7 to 9V dc from 1kΩ ±10%

  • Input/output characteristics

    Normal phase

    Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

    Outputs open if input < 1.2mA (> 10kΩ in input circuit)

    Hysteresis: 200µA (650Ω) nominal

  • Line fault detection (LFD) (when selected)

    User-selectable via switches on the side of the unit. Line faults

    are indicated by an LED. Line fault relay is energised and channel

    output relay de-energised if input line-fault detected

    Open-circuit alarm on if Iin < 50µA

    Open-circuit alarm off if Iin > 250µA

    Short-circuit alarm on if Rin < 100Ω

    Short-circuit alarm off if Rin > 360Ω

    Note: Resistors must be fitted when using the LFD facility with a contact input

    500Ω to 1kΩ in series with switch

    20kΩ to 25kΩ in parallel with switch

  • Safe-area output

    Channel: Single pole relay with changeover contacts

    LFD: Single pole relay with changeover contacts

    Note: reactive loads must be adequately suppressed

13.jpg

 

 

 

 

 

 

HCU16 MTL5521 MTL4575
HCU3700 MTL5522 MTL4646Y
HM64RIB20-1.0 MTL5531 MTL4850
HM64RIB20-1.5 MTL5532 MTL4851
HMM64 MTL5541 MTL4852
HMRIB16-1.0 MTL5541S MTL5018
HMS64 MTL5544 MTL5032
HTP-SC32 MTL5544D MTL5042
MTL4044D MTL5546 MTL5044
MTL4511 MTL5546Y MTL5049
MTL4516 MTL5561 MTL5511
MTL4516C MTL5573 MTL5514D
MTL4521 MTL5575 MTL5516
MTL4541 MTL5582B MTL5516C
MTL4541 MTL7728+ MTL7787P+
MTL4544 MTL7756AC MTLCPS16
MTL4544D MTL7760AC NJ5-18GK-N
MTL4546Y MTL7761PAC SD150X
MTL4549Y MTL7765AC SD32
MTL4573 MTL7787+ SD32X
TP48-4-N-NDI TP48-3-N-NDI SDRTD
TP48-N-NDI TP48-4-I-NDI SLP32D

 

 

Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Achievers Automation Limited
Location RM 509, 5/F, THE CLOUD, 111,TUNG CHAU STREET, TAI KOKTSUI, KOWLOON,HONG KONG
Contact Person Joanna Yang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.