100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface

Price Negotiable
Price: Negotiate
MOQ: 1
Delivery Time: stock
Brand: MTL
Product Description

 

MTL5511 MTL Instruments Switch Proximity Detector Interface 10ms Maximum

 

The MTL5511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line-fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts

 

  • Number of channels

    One

  • Location of switches

    Zone 0, IIC, T6 hazardous area

    Div. 1, Group A hazardous location

  • Location of proximity detector

    Zone 0, IIC, T4–6 hazardous area if suitably certified

    Div. 1, Group A hazardous location

  • Hazardous-area inputs

    Inputs conforming to BS EN60947–5–6:2001 standards for

  • proximity detectors (NAMUR)

    Voltage applied to sensor

    7 to 9V dc from 1kΩ ±10%

  • Input/output characteristics

    Normal phase

    Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

    Outputs open if input < 1.2mA (> 10kΩ in input circuit)

    Hysteresis: 200μA (650Ω) nominal

  • Line fault detection (LFD) (when selected)

    User-selectable via switches on the side of the unit. A line fault is

    indicated by an LED. The channel output relay is de-energised if

    an input line fault is detected.

    Open-circuit alarm on if Iin < 50μA

    Open-circuit alarm off if Iin > 250μA

    Short-circuit alarm on if Rin < 100Ω

    Short-circuit alarm off if Rin > 360Ω

    Note: Resistors must be fitted when using the LFD facility with a contact

    input

    500Ω to 1kΩ in series with switch

    20kΩ to 25kΩ in parallel with switch

    Safe-area output

    Single pole relay with changeover contacts

    Note: reactive loads must be adequately suppressed

  • Relay characteristics

    Response time: 10ms maximum

    Contact rating: 250V ac, 2A, cosØ >0.7

    40V dc, 2A, resistive load

 

1736928209357.png

HCU16 MTL5521 MTL4575
HCU3700 MTL5522 MTL4646Y
HM64RIB20-1.0 MTL5531 MTL4850
HM64RIB20-1.5 MTL5532 MTL4851
HMM64 MTL5541 MTL4852
HMRIB16-1.0 MTL5541S MTL5018
HMS64 MTL5544 MTL5032
HTP-SC32 MTL5544D MTL5042
MTL4044D MTL5546 MTL5044
MTL4511 MTL5546Y MTL5049
MTL4516 MTL5561 MTL5511
MTL4516C MTL5573 MTL5514D
MTL4521 MTL5575 MTL5516
MTL4541 MTL5582B MTL5516C
MTL4541 MTL7728+ MTL7787P+
MTL4544 MTL7756AC MTLCPS16
MTL4544D MTL7760AC NJ5-18GK-N
MTL4546Y MTL7761PAC SD150X
MTL4549Y MTL7765AC SD32
MTL4573 MTL7787+ SD32X
TP48-4-N-NDI TP48-3-N-NDI SDRTD
TP48-N-NDI TP48-4-I-NDI SLP32D

 

 

Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Achievers Automation Limited
Location RM 509, 5/F, THE CLOUD, 111,TUNG CHAU STREET, TAI KOKTSUI, KOWLOON,HONG KONG
Contact Person Joanna Yang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.