Quality Pneumatics Filter Air dryer Filter
The working principle of Compressed Air Filter:
Gravity effect: When the air velocity in the filter is low, most of the oil droplets with a diameter of 20-50um are collected by free fall by gravity before reaching the filter layer. Moreover, the airflow continues to fall and collect as it flows through the filter. The greater the air velocity, the lower its efficiency.
Inertial impaction: Generally, suspended particles with a diameter greater than 1um have a large impulse. It is not always consistent with the air flow path, so it will inertially hit the fiber layer. The greater the air velocity, the greater the collision rate.
Direct interception: particles with a diameter of 0.3-1um move with the airflow, and most of them will be intercepted and separated by the fiber layer at 1/2 of the Filter Element. The smaller the particle, the lower the interception rate.
Penetration: particles with a diameter of less than 0.3um. Because the mass is too small to have the versatility of liquids, they move in an irregular Brownian motion. It is inconsistent with the air flow path, and it is precisely because of this movement that it can be captured by a finer filter layer. The smaller the particles. The more intense the Brownian motion, the greater the chance of catching it.
| PF | AO | AA | AX | ACS | AR | AAR |
| As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
| Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
| L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
| YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
| YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
| YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
| YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
| YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
| YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
| YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
| YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
| YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
| YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
| YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
| YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
| YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
| YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
| YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
| Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C | |||||||||
| Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
| Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 | |


Successful Case

YUKA Delivery

YUKA service:
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty
Q:Why choose us?
a. 24 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.
Frequently Asked Questions:
Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.
Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production.
Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.
Q4. Do you have a warranty?
Yes, for filter, it is 1 year normally.
Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.