Air Compressor Filter for Nitrogen Generator
How Does a Compressed Air Filter Work?
Air compressor filter does is keep water, oil and dirt from down to your pneumatic tools, making them essential to the overall health of your air system. These kinds of dust or particles can damage or destroy your equipment if you don’t offer proper filtration. If they pass through those tools, your project will be affect in negatively, such as by destroying a paint job or contaminating foods in production facilities.
One of the benefits of Air Filters is that they are reasonable investments. What you have to keep up with wear and replace them in time, it costs far less to purchase new filters than to pay for repair costs for damaged pneumatic equipment or air compressors. You’ll receive result in positive, as keeping the air that passes through your compressor clean is critical to tool and equipment health as well as work quality.
YUKA YF-B Series Feature & Benefit
>HV fiber glass Element Material, ensure filtration performance up to ISO8573.1-2010 Standard
>Aluminium alloy die-casting filter housing, spanlife with 15 years
>Stainless Steel Filter element supports mesh to prevent the secondary pollution from flowing to the back end of the compressed air
>7 filtration grades to removel for different contaminate well
>Flow rate from 1.0 to 48m³/min,
>Maximum operating pressure: 16 bar(g)
>Maximum operating temperature: 80 °C
7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
| PF | AO | AA | AX | ACS | AR | AAR |
| As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
| Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
| Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
| Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
| Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
| Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Product Picture
Technical Specification
For application in other working pressure, please refer to the correction factors.
| Model | Pipe size | Flow rates | Dimension (mm) | |||||||
| L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
| YF-B010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 245 | 29 | 180 | 118 |
| YF-B020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 245 | 29 | 180 | 118 |
| YF-B030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 274 | 29 | 209 | 153 |
| YF-B040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 274 | 29 | 209 | 153 |
| YF-B060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 349 | 37 | 276 | 208 |
| YF-B070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 450 | 37 | 377 | 303 |
| YF-B080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 450 | 37 | 377 | 303 |
| YF-B090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
| YF-B100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
| YF-B110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
| YF-B120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
| YF-B130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 616 | 74 | 542 | 514 |
| YF-B140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 616 | 74 | 542 | 514 |
| YF-B150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 892 | 74 | 798 | 764 |
| YF-B160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 892 | 74 | 798 | 764 |
| Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C | |||||||||
| Pressure | Barg | 1 | 2 | 3 | 4 | 5 |