GREAT SYSTEM INDUSTRY CO. LTD
                                                                                                           
Verified Supplier
28 Years
Since 1998
Menu

MTL 5541 Repeater Power Supply 20-35VDC DIN Rail

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: on request
Brand: MTL
Product Description
MTL 5541 Repeater Power Supply 20-35VDC DIN Rail
Quick Detail of Repeater Power Supply
  • Manufacturer: MTL Instruments
  • Product No.: MTL5541
  • Product Type: Repeater Power Supply
  • Number of channels: One
  • Location of transmitter: Zone 0, IIC, T4-6 hazardous area if suitably certified Div. 1, Group A hazardous location
  • Safe-area circuit ripple: < 50µA peak-to-peak
  • Transfer accuracy at 20°C: Better than 15µA
  • Temperature drift: < 0.8µA/°C
  • Response time: Settles to within 10% of final value within 50µs
  • Communications supported: HART® (terminals 1 & 2 only)
  • LED indicator: Green: power indication
  • Maximum current consumption (with 20mA signal): 51mA at 24V
  • Dimensions (LxWxH): 1.58 cm x 10.98 cm x 12.36 cm
  • Weight: 0.11 Kg
Description of Repeater Power Supply
The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load.
Specification of Repeater Power Supply
Hazardous Area Input Signal range: 0-24 mA (including over-range); Transmitter voltage: 16.5 V at 20 mA
Safe Area Output Signal range: 4-20 mA; Under/over-range: 0-24 mA; Load resistance: 0 to 360Ω @ 24 mA, or 0 to 450Ω @ 20 mA; Current sink: 600Ω max.; Maximum voltage source: 24 VDC; Output resistance: > 1 MΩ
Power Requirement 20-35 VDC.
Response Time Settles to within 10% of final value within 50 µs
Current Consumption 51 mA @ 24V
Maximum Power Dissipation 0.7 W @ 24 VDC, 1.0 W @ 24 VDC
Isolation 250 V RMS, tested at 1500 V RMS minimum, between safe-area and hazardous-area terminals; 50 V between safe-area circuits and power supply
Transfer Accuracy at 68°F (20°C) Better than 15 µA
LED Indicator Green: Power indication
Temperature Limits Operating: -6 to 140°F (-20 to 60°C); Storage: -40 to 176°F (-40 to 80°C)
Temperature Drift < 0.8µA/°C
Humidity 5 to 95% RH
Mounting T-section 35 mm DIN rail (7.5 or 15 mm) to EN 50022
Terminals Accommodate up to 2.5 mm2 stranded or single-core
Safety Description Vo= 28 V, Io= 93 mA, Po= 651mW, Um= 253 RMS or DC
Weight 150g
MTL 5541 Repeater Power Supply front view MTL 5541 Repeater Power Supply side view MTL 5541 Repeater Power Supply installation view MTL 5541 Repeater Power Supply technical details
Advantage of Our Team
  • Best possible prices and delivery time
  • Long time experience in the field
  • Well trained staff
  • Own warehouse facilities
  • Best relationships with branch office of manufacture
  • Flexible and individual service for you
  • Cheap and safe forwarder for shipments (air)

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company GREAT SYSTEM INDUSTRY CO. LTD
Location Flat 10, 6/F, Block A, Hi-Tech Ind. Ctr. 5-21 Pak Tin Par St, Tsuen Wan, HK
Contact Person Jim

Request A Quote

Please check your email address.
Your message must be at least 20 characters.