MTL5514 Switch / Proximity Detector Interface Normal Phase
Price:
Negotiable
MOQ:
1
Delivery Time:
on request
Brand:
MTL
Product Description
MTL5514 Switch / Proximity Detector Interface Normal Phase
Quick Detail of Detector Interface
- Number of channels: One
- Location of switch: Zone 0, IIC, T6 hazardous area
- Div.1, Group A, hazardous location
- Location of proximity detector: Zone 0, IIC, T4-6 hazardous area (if suitably certified)
- Div.1, Group A, hazardous location
- Hazardous-area inputs conform to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR)
Description of Detector Interface
The MTL5514-T enables a safe-area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
Specification of Detector Interface
| Number of channels | One |
|---|---|
| Location of switch | Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location |
| Location of proximity detector | Zone 0, IIC, T4-6 hazardous area, if suitably certified Div.1, Group A, hazardous location |
| Hazardous-area inputs | Inputs conforming to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR) |
| Voltage applied to sensor | 7 to 9V dc from 1kΩ ±10% |
| Input/output characteristics |
Normal phase Outputs closed if input > 2.1mA (< 2kΩ in input circuit) Outputs open if input < 1.2mA (> 10kΩ in input circuit) Hysteresis: 200µA (650Ω) nominal |
| Line fault detection (LFD) (when selected) |
User-selectable via switches on the side of the unit. Line faults are indicated by an LED. Line fault relay is energised and channel output relay de-energised if input line-fault detected Open-circuit alarm on if Iin < 50µA Open-circuit alarm off if Iin > 250µA Short-circuit alarm on if Rin < 100Ω Short-circuit alarm off if Rin > 360Ω Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch |
| Safe-area output |
Channel: Single pole relay with changeover contacts LFD: Single pole relay with changeover contacts Note: reactive loads must be adequately suppressed |
Features of Detector Interface
- 1-channel interface
- Line fault detection capability
- Phase reversal functionality
Our Advantages
- Best possible prices and delivery time
- Long time experience in the field
- Well trained staff
- Own warehouse facilities
- Best relationships with branch office of manufacture
- Flexible and individual service for you
- Cheap and safe forwarder for shipments (air)
Frequently Asked Questions
Q: Does your goods are new and original?
A: Yes, they are new and original.
Q: How long warranty?
A: One-year warranty.
Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with our sales.
Q: Varied payment methods.
A: We adopt T/T, alipay and paypal and Currency in EURO,USD,RMB.
Q: SHIPPING:
A: We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.
Our Product Range
Transmitter, Safety barries, Flow meters, Probe, Sensor, Transducer. Valves, Analysis meter, Positioner, Acuator, etc.