8800p Al2O3 Trace Teledyne Analytical Instruments Gas Moisture Analyzer
Part Number: 8800P
Product Name: Trace Moisture Analyzer
Origin: USA
Manufacturer: Teledyne
The 8800 Series Single Point Trace Moisture Analyzers are provided in four compact, reliable designs with the ability to detect moisture from -148°F (-100°C) to ambient dew point levels of +68°F (+20°C) on either a continuous or spot checking basis.
- 8800A - Flush Mount DIN enclosure with connections made via a pluggable screw terminal block
- 8800B - Wall Mount N4X (IP65) enclosure with connections made with 3 bottom watertight fittings
- 8800P - Portable battery operated design in the Standard, I/O and I/S versions (I/S is suitable for hazardous areas)
- 8800T - Low-cost, loop powered 4-20 mA transmitter design with built-in LCD display
- Readout available in (5) engineering units; °C, °F, ppm, lbs. H2O/mm scf & g H2O/m3
- Scalable signal outputs (0-20 mADC & 4-20 mADC)
- Built-in LCD with backlight, 3.5 digits and custom legends for units / mode
- Din box enclosure: (cut-out dimensions of 137 mm W x 67 mm H)
- (4) front panel membrane tactile push button controls, all settings stored in EEPROM
- (2) programmable alarm relays w/programmable variable hysteresis rated 10A @ 240V
- Power requirements of 100-240 VAC, 50 or 60 Hz
- Operating temperature of electronics: -10 to 50° C
- Class I & II, Division 1, Groups A, B, C, D, E, F & G (when used with optional safety barriers)
- High capacitance aluminum oxide (Al2O3) sensor using Hyper Thin Film (HTF)™ Technology
- (2) meters of sensor interconnection cable included
- Power cord
- Instruction manual (one copy per analyzer ordered)
| Model | Part Number | Description | Application |
|---|---|---|---|
| A-2C | C6689-A2C | Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
| A-2CXL | B74033-A2CXL | Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
| A-5 | C6689-A5 | Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. | Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration. |
| B-1 | C6689-B1 | General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). | Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas. |
| B-2C | C6689-B2C | General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. |
| INSTA TRACE | B71875 | Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. | Used for trace O2 analysis in inert gas and hydrocarbon streams. |
- Best possible prices and delivery time
- Long time experience in the field
- Well trained staff
- Own warehouse facilities
- Best relationships with branch office of manufacture
- Flexible and individual service for you
- Cheap and safe forwarder for shipments (air)
A: Yes, they are new and original.
A: One-year warranty.
A: Yes, it depends on what product you request, please check details with our sales.
A: We adopt T/T, alipay and paypal and Currency in EURO,USD,RMB