RF-250 22mm Brush Carbon Motor 1500rpm-13000rpm High Speed Mute Motor For Smoke Vents
RF-250 22mm Brush Carbon Motor 1500rpm-13000rpm High Speed Mute Motor For Smoke Vents
RF-250 Metal Brush Motor DC Technical Parameters
- Motor Name/Type:RF-250SH-13320 Mini motor
- Rated Voltage: 12.0VDC
- Staring Voltage:1.5V
- Operating Volt:11v-13V
- Rated Load Torque:60g.cm
- No-load Current: 55mA max
- No-load Speed: 5400±540r/min
- Rated Load Speed:3500±350r/min
- Rated Load Current:420mA
- At Maximum Efficiency Speed: 4548r/min
- At Maximum Current:0.152A max
- At Maximum Torque:2.688mN.m
- At Maximum Output: 1.19 w
- At Maximum Efficiency:65.5%
- Stall Current: 0.796A
- Stall Torque:16.77mNm
- At Maximum Power Output
- Output:2.218w
- Torque:8.385mN.m
- Speed:2913rpm
- Current:0.38A
- Body Size: 30.5mm x 22mm (L*D)
- Shaft Size: 2mm diameter
- Weight: 38 grams
- Operating Temperature: -20°C ~ +70°C
- Storage Temperature Range:-30°C ~ +80°C
- Direction of Rotation:CCW
RK-250 High Speed Brush Carbon Motor Dimension
RK-250 Micro Motor Dimension Information
1.Motor Shell Size:22mm Diameter*30.5 Length (Length without output shaft length)
2.Front Step Diameter:6mm
3.Front Step Height:1.5mm
4.Output Shaft Length:20mm/6mm/9mm/10mm or Custom
5.Terminal Distance:15.2mm
6.Mounting Screw Holes Distance:14mm
7.Screw Holes Size:2*0.4mm
8.Terminal Height:2.5mm
9.Notes
1. Usable machine screw | ength 1. 0max. from motor mounting surface.
2. Allowable torque for screwing of tapped hole:2. 5kgf-cm max.
3. No remarkable scraches on dents on the surface.
4. Tolerances not otherw ise specified decimal:土0.3mm.
RK-250 DC Motor 22mm Mini Motor TN Curve
RF-250 DC Motor: The Optimal Drive Solution for Emergency Smoke Ventilation Systems
Key Technical Specifications
-
Brand: HCS Motor/Lihua Motors
-
Type: Brushed DC Motor
-
Certification: ISO9001/CE/Rohs /Reach
-
Customization: Available
-
Rated Power: 5W
-
Voltage Range: 6.0V~28.0V (12V constant voltage recommended)
-
Speed: 5000 RPM (rated), 7500 RPM (max)
-
Torque: 0.006 Nm (rated), 306 g-cm (stall)
-
Efficiency: 80% (peak efficiency at 7321 RPM, 0.47A, 4.83 g-cm)
-
Response Time: ≤2S braking
-
Dimensions: Ø22mm × 30.5mm
-
Weight: 60g
-
Insulation Class: F
Why RF-250 Excels in Smoke Ventilation?
-
Instant Emergency Activation
-
Achieves full speed in seconds, ensuring rapid window opening for smoke extraction.
-
High stall torque (306 g-cm) overcomes initial resistance in window mechanisms.
-
-
Robust Design for Critical Environments
-
Wide voltage tolerance (6V–28V) guarantees operation during voltage fluctuations.
-
Class F insulation withstands high temperatures in fire scenarios.
-
-
Smart System Integration
-
Compatible with fire alarm interfaces for automated triggering.
-
Low standby current (0.47A at peak efficiency) reduces energy waste.
-
-
Compact & Lightweight
-
Minimal space requirements (22mm diameter) for retrofit installations.
-
Aluminum housing enhances heat dissipation in continuous duty cycles.
-
Typical Applications
-
Industrial: Factory skylights, warehouse vents
-
Commercial: Shopping mall atriums, office building smoke shafts
-
Public Spaces: Hospitals, stadiums, subway stations
-
High-Rise Buildings: Complies with international smoke control standards
Performance Comparison
| Parameter | RF-250 | Standard Motors |
|---|---|---|
| Response Time | <2s | 3–5s |
| Voltage Range | 6–28V DC | 12V±10% |
| Peak Efficiency | 80% @ 7321 RPM | 65–75% |
| Stall Torque | 306 g-cm | 200–250 g-cm |
Note: Custom winding options available for specific voltage/speed requirements. Third-party fire safety certifications (UL/EN) can be provided upon request.
For critical life-safety applications, the RF-250's blend of rapid response, compact size, and fault-tolerant design makes it the preferred choice for modern smoke ventilation systems.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.