24kW Rubber Removal Hot Air Drying Oven Industrial Muffle Furnace
| Attribute | Value |
|---|---|
| Product Name | Hot Air Rubber Removal Furnace |
| Range of Applications | Industrial |
| Type | Electric Holding Furnace |
| Usage | Ceramic Drying |
| Fuel | Electric |
| Atmosphere | Air |
| Effective Chamber Dimensions | 600*600*600mm(W*H*D) |
| Transport Package | Wooden Packaging |
| Specification | 1300*1710*1800mm(W*H*D) |
| Trademark | Chitherm |
| Origin | China |
| HS Code | 8514101000 |
| Production Capacity | 50 Sets/Year |
Chitherm Hrf216-07 Hot Air Rubber Removal Furnace with Effective Chamber Dimensions 600*600*600mm
Mainly used for binder burning out (BBO) process of electronic components and ceramic substrates.
- Rated Temperature: 600ºC
- Maximum Temperature: 650ºC
- Effective Dimensions: 600 × 600 × 600mm (W×H×D)
- Heating Method: Stainless Steel Heater
- Process Atmosphere: Air
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±5ºC (insulation 1 hour at 400ºC test)
- Thermocouple: Type K
- Temperature control points: 1
- Temperature measurement points: 1 point
- Process Steps: 4 × 16 steps
- Exhaust: One exhaust port on top
- Alarm System: Over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
- Maximum Heating Power: 24kW
- Insulation Power: ≤ 12kW
- Surface Temperature Rise: ≤ 35ºC
- Weight: about 1000kg
- Furnace Dimensions: about 1300×1710×1800mm (W×H×D)
- Appearance Color: light gray
| Item | Note | QTY |
|---|---|---|
| Basic Compositions | ||
| Dryer | 1 PC | |
| Certificates of Inspection | Dryer and major purchased components | 1 Set |
| Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set |
| Key Parts | ||
| Heating Elements | Stainless Steel Heater | 1 Set |
| Thermocouple | WATLOW/THERMOWAY, Type K | 1 PC |
| Air circulator | Water cooling fan | |
| Temperature Controller | 1 Set | |
| Monitor | Touch screen | 1 Set |
| Spares | ||
| SSR | 1 PC | |
Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong airflow disturbance.
Clean compressed air, pressure 0.2 - 0.4Mpa, gas consumption 3-7m3/h.
Non-contact access to the user pumping system, pumping capacity greater than 10m3/h.
Level, no obvious vibration, bearing capacity >300Kg/m2.
Capacity greater than 32kVA, 3 phases 5 lines, voltage 220/380V, frequency 50Hz (according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green.
2000mm×3000mm×3000mm (W×H×D), installation area greater than 6m2.
Get in Touch