HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy
Price:
Negotiable
MOQ:
1
Delivery Time:
90 work days
Brand:
Chitherm
Product Description
HWF80-04N Series Precision Atmosphere-Controlled Vacuum Furnace Muffle Furnace
Basic Equipment Information
| Item | Details |
|---|---|
| Equipment Model | HWF80-04N Type Hydrogen Removal Furnace |
| Application Field | Heat treatment processes such as decarburization, hydrogen removal, annealing, tempering, and binder removal |
| Equipment Weight | Approximately 1000kg |
| Equipment Color | Light gray |
| Reference Overall Dimensions | 1500×1950×1750mm (W×H×D), subject to the actual product |
| Installation Site Dimensions | 3000mm×2500mm×3000mm (D×W×H), installation area ≥8m² |
Core Technical Indicators
Temperature-related
- Rated Temperature: 350ºC (unlimited holding time); Maximum Temperature: 400ºC
- Heating Rate: ≤5ºC/min; Temperature Control Accuracy: ±1ºC (with PID parameter self-tuning function)
- Temperature Uniformity: ±5ºC (tested in empty furnace at 350ºC for 1h under constant temperature)
- Cooling Method: Furnace cooling (time from 350ºC to room temperature <12h)
- Heating Method: Hot air circulation heating
- Heating Element: Internal heating with stainless steel heating tubes
- Maximum Heating Power: 15kW; Empty Furnace Holding Power: ≤7.5kW
- Thermocouple Type: K grade
- Temperature Control Points: 1 point (reserved detection port for installing armored flexible thermocouple for real-time monitoring)
Atmosphere and Vacuum-related
- Sintering Atmosphere: Vacuum/Nitrogen
- Ultimate Vacuum Degree: 10-²Pa (empty furnace, clean, room temperature, fully degassed)
- Vacuum Pumping Time: ≤60min (from atmospheric pressure to 10-²Pa)
- Oxygen Content: Better than 50ppm (under positive pressure inert atmosphere)
- Equipped with a micro-oxygen analyzer to detect oxygen content inside the tank
- Number of Exhaust Ports: 1
Structure and Safety
- Tank Material: SUS316L
- Effective Dimensions: 400×400×500mm (W×H×D)
- Loading Method: Manual loading, with horizontal guide rails and racks inside the tank
- Surface Temperature Rise: <35ºC
- Alarm Protection: Acoustic and optical alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, motor under/over phase, etc., and over-temperature alarm to cut off heating protection function
Installation and Operation Conditions
- Environmental Conditions: Temperature 0~40ºC, Humidity ≤80%RH, no corrosive gas, no strong air disturbance
- Nitrogen: Pressure 0.2~0.4Mpa, Purity 99.999%, Gas Consumption 2~6m³/h
- Compressed Air: Clean, dry, oil-free, Pressure 0.4~0.8Mpa
- Water Inlet Conditions: Pressure 0.1~0.3Mpa, clean, non-corrosive, supply flow rate 1~3L/min
- Ventilation System: Non-contact connection to the user's air extraction system, extraction capacity >10m³/h
- Ground Requirements: Level, no obvious vibration, load-bearing capacity >500kg/m²
- Power Conditions: Capacity >22kVA, 3-phase 5-wire, Voltage 220/380V, Frequency 50Hz (Live wire: Yellow/Green/Red, Neutral wire: Blue, Ground wire: Yellow-green)