Multi Core XLPE Insulated Power Cable Cu Conductor Fire Proof Cable with XLPE Insulation EN 60332
Multi Core XLPE Insulated Power Cable Cu Conductor Fire Proof Cable with XLPE Insulation EN 60332
APPLICATION
- Industrial Facilities
Widely used in petrochemical plants, steel mills, and power stations due to its high-temperature resistance (up to 90°C continuous operation) and flame-retardant properties (compliance with IEC 60332-3-22 for group flame spread limits) - High-Rise Buildings & Underground Installations
Essential for fire safety in vertical shafts, cable tunnels, and emergency circuits where low smoke toxicity (halogen-free) is critical to prevent secondary hazards during fires. - Public Infrastructure
Deployed in metro systems, hospitals, and data centers where fireproofing and continuous power supply are mandatory (e.g., BS 6387 standard for fire survival duration). - Offshore & Marine Environments
Resistant to moisture and corrosion, suitable for shipboard wiring and offshore platforms (meets IEC 60092-350 for marine cable standards).
CONSTRUCTION
- Conductor: Class 1/Class 2 stranded Copper conductor
- Refractory layer:Single sided gold mica tape
- Insulation:XLPE
- Filler(options):Polypropylene mesh tear rope or flame-retardant filling
- Outer sheath:Polyvinyl chloride (PVC)
CHARACTERISTICS
- Voltage Rating: Uo/U:0.6/1kV Um:1.2kV
- Maximum operating temperature of conductor:+90℃
- Operating ambient temperature: -15℃~+55℃
- Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
- Minimum Bending Radius: Single core:20D multi core:15D
SPECIFICATIONS
|
Spec |
Conductor diameter mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
||||||
|
NH |
ZAN |
ZBN |
ZCN |
NH |
ZAN |
ZBN |
ZCN |
||
|
3×16 |
5.0 |
18.9 |
192 |
192 |
19.2 |
659.4 |
713.1 |
719.2 |
680.1 |
|
3×25 |
6.1 |
22.5 |
22.5 |
22.5 |
22.5 |
974.7 |
1044.6 |
1051.8 |
996.1 |
|
3×35 |
72 |
24.8 |
24.8 |
24.8 |
24.8 |
1274.1 |
1361.6 |
1369.6 |
1300.0 |
|
3×50 |
8.4 |
27.9 |
28.3 |
27.9 |
27.9 |
1659.7 |
1806.0 |
1775.4 |
1692.0 |
|
3×70 |
10.0 |
32.0 |
32.4 |
32.0 |
32.0 |
2320.7 |
2510.1 |
2474.6 |
2362.4 |
|
3×95 |
12.0 |
36.4 |
36.9 |
36.4 |
36.4 |
3132.4 |
3375.7 |
3334.7 |
3185.7 |
|
3×120 |
12.2 |
37.5 |
37.9 |
37.5 |
37.5 |
3797.7 |
4053.5 |
4010.8 |
3853.6 |
|
3×150 |
13.6 |
41.8 |
41.8 |
41.8 |
41.8 |
4681.2 |
4957.1 |
49455 |
4749.1 |
|
3×185 |
15.2 |
46.3 |
46.3 |
46.3 |
46.3 |
5813.6 |
6154.0 |
6133.9 |
5896.1 |
|
3×240 |
17.4 |
51.9 |
51.9 |
51.9 |
51.9 |
7519.6 |
7947.6 |
7923.0 |
7621.7 |
|
3×300 |
19.5 |
572 |
57.2 |
57.2 |
57.2 |
9355.8 |
9847.1 |
9847.1 |
9478.3 |
|
3×400 |
22.0 |
64.0 |
64.0 |
64.0 |
64.0 |
11858.3 |
12473.0 |
12473.0 |
12009.4 |
|
4×1.5 |
1.39 |
12.0 |
12.3 |
12.3 |
12.3 |
186.2 |
201.4 |
201.4 |
201.4 |
|
4×2.5 |
1.76 |
12.9 |
13.2 |
13.2 |
12.9 |
236.7 |
252.8 |
252.8 |
241.3 |
|
4×4 |
2.22 |
14.0 |
14.3 |
14.3 |
14.0 |
3092 |
327.2 |
327.2 |
314.2 |
|
4×6 |
2.74 |
15.3 |
15.6 |
15.6 |
15.3 |
402.2 |
422.6 |
422.6 |
407.8 |
|
4×10 |
4.0 |
18.3 |
18.6 |
18.6 |
18.6 |
588.5 |
634.7 |
640.6 |
607.4 |
|
4×16 |
5.0 |
21.0 |
21.0 |
21.0 |
21.0 |
845.5 |
900.0 |
906.7 |
863.1 |
|
4×25 |
6.1 |
24.7 |
24.7 |
24.7 |
24.7 |
1250.8 |
1328.7 |
1336.6 |
1274.7 |
|
4×35 |
72 |
27.4 |
27.4 |
27.4 |
27.4 |
1643.6 |
1741.3 |
1750.2 |
1672.6 |
|
4×50 |
8.4 |
30.9 |
31.4 |
30.9 |
30.9 |
2163.3 |
2326.9 |
2292.5 |
2199.4 |
|
4×70 |
10.0 |
35.5 |
35.9 |
35.5 |
35.5 |
3031.9 |
3243.8 |
3203.9 |
3078.4 |
|
4×95 |
12.0 |
40.5 |
41.0 |
40.5 |
40.5 |
4098.6 |
4370.6 |
4324.5 |
4158.1 |
|
4×120 |
12.2 |
41.8 |
42.3 |
41.8 |
41.8 |
4998.3 |
5285.4 |
5236.4 |
5060.6 |
|
4×150 |
13.6 |
46.4 |
46.4 |
46.4 |
46.4 |
6136.1 |
6444.3 |
6430.9 |
6211.8 |
|
4×185 |
15.2 |
51.6 |
51.6 |
51.6 |
51.6 |
7649.6 |
8031.2 |
8006.8 |
7741.8 |
|
4×240 |
17.4 |
57.8 |
57.8 |
57.8 |
57.8 |
9896.6 |
10376.0 |
10346.5 |
10010.5 |
|
4×300 |
19.5 |
63.7 |
63.7 |
63.7 |
63.7 |
12314.4 |
12861.8 |
12861.8 |
12451.0 |
|
4×400 |
22.0 |
71.3 |
71.3 |
71.3 |
71.3 |
15606.1 |
16291.7 |
16291.7 |
15774.6 |
|
5×1.5 |
1.39 |
13.0 |
13.3 |
13.3 |
13.3 |
218.6 |
235.5 |
235.5 |
235.5 |
|
5×2.5 |
1.76 |
14.0 |
14.3 |
14.3 |
14.0 |
280.8 |
298.8 |
299.5 |
285.8 |
|
5×4 |
2.22 |
152 |
15.5 |
15.5 |
15.2 |
369.9 |
391.0 |
391.0 |
375.4 |
|
5×6 |
2.74 |
16.6 |
16.9 |
16.9 |
16.6 |
484.6 |
508.5 |
508.5 |
490.7 |
|
5×10 |
4.0 |
20.4 |
20.4 |
20.4 |
20.4 |
7192 |
769.4 |
776.9 |
7356 |
|
5×16 |
5.0 |
23.1 |
23.1 |
23.1 |
23.1 |
1031.4 |
1097.7 |
1106.4 |
1052.2 |
|
5×25 |
6.1 |
27.2 |
27.2 |
27.2 |
27.2 |
1533.7 |
1628.8 |
1637.6 |
1562.1 |
|
5×35 |
72 |
30.1 |
30.1 |
30.1 |
30.1 |
2021.3 |
2140.4 |
2150.2 |
2055.8 |
|
5×50 |
8.4 |
34.2 |
34.7 |
34.2 |
34.2 |
2680.5 |
2876.9 |
2838.3 |
2723.7 |
|
5×70 |
10.0 |
39.3 |
39.8 |
39.3 |
39.3 |
3760.0 |
4014.9 |
3970.1 |
3815.8 |
|
5×95 |
12.0 |
45.1 |
45.5 |
45.1 |
45.1 |
5107.2 |
5436.4 |
5383.7 |
5178.7 |
|
5×120 |
12.2 |
46.3 |
46.7 |
46.3 |
46.3 |
6204.7 |
6550.6 |
6495.8 |
6279.6 |
|
5×150 |
13.6 |
51.6 |
51.6 |
51.6 |
51.6 |
7643.2 |
8020.9 |
8004.6 |
7734.5 |
|
5×185 |
15.2 |
57.4 |
57.4 |
57.4 |
57.4 |
9525.2 |
9992.5 |
9963.3 |
9636.4 |
|
5×240 |
17.4 |
64.2 |
64.2 |
64.2 |
64.2 |
12322.0 |
12909.5 |
12874.3 |
12459.9 |
Contact us for more details
OUR FACTORY
PROJECTS
PARTNERS
WHY US
FAQ
Q. What is the maximum operating temperature of multi-core XLPE insulated copper conductor fire-proof cables?
A. The continuous operating temperature is typically 90°C (IEC 60502-2 compliant) with short-circuit withstand capability up to 250°C for 5 seconds
Q. Which fire safety standards do these cables comply with?
A. They meet IEC 60332-3-22 (flame spread in vertical installations) and IEC 60331 (fire resistance duration, e.g., 90 minutes at 750°C)
Q.Where are these cables commonly installed?
A. Critical applications include high-rise buildings (emergency circuits), subway tunnels (low-smoke requirements), and power plants (high mechanical stress areas)
Q. What is the difference between flame-retardant and fire-resistant versions?
A. Flame-retardant cables slow flame propagation (IEC 60332-1), while fire-resistant cables maintain circuit integrity during fires (IEC 60331)
Q. Can these cables be used in underground or marine environments?
A. Yes, with steel wire armor (SWA) for underground burial (IEC 60502-2) or halogen-free sheaths for marine corrosion resistance
Q. What conductor materials are available besides copper?
A. Aluminum-core variants exist (e.g., AAAC conductors) but offer lower conductivity (≈61% of copper) and higher weight
Q. How many cores can these cables have?
A. Standard configurations include 1-5 cores (single-phase to three-phase systems), with options for concentric grounding conductors
Q.Do these cables require special installation precautions?
A. Avoid sharp bending (minimum bending radius: 12× cable diameter) and overheating during welding near PVC sheaths
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.