Zhongdong Cable Co., Ltd.
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

6.35/11kV & 12.7/22kV Non Screened ABC –Aerial Bundled Cables to AS NZS 3599.1 AL/XLPE/HDPE

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 7-30 days based on different qty
Brand: Aerial Bundled Cables
Product Description

6.35/11kV & 12.7/22kV Non Screened ABC –Aerial Bundled Cables to AS NZS 3599.1 AL/XLPE/HDPE



Applicatiom

  • ‌Primary/Secondary Distribution‌: Ideal for urban/rural electrification with ‌enhanced safety‌ (reduced outage risks).
  • ‌Bare Transmission‌: Utilized as overhead conductors in high-voltage grids.
  • ‌Hybrid Systems‌: Compatible with ‌ACSR (Aluminum Conductor Steel Reinforced)‌ for strength-optimized designs.

Characteristics

  • Rated Voltage: 0.6/1 Kv,6.35/11kV,12.7/22kV Up to 33KV
  • Number of Cores: 2-5 Core

Technical Advantages‌

  • ‌Variable Steel Core Stranding‌: Balances mechanical strength (e.g., wind loading) and ‌ampacity‌ (current-carrying capacity).
  • ‌Electrified Wire Netting‌: Integrates with smart grid infrastructure to improve ‌reliability‌ and fault detection.
  • ‌Compliance‌: Meets AS/NZS 3599.1 standards for durability and performance in harsh environments.

Specification

number of cores x nominal cross section Nominal conductor diameter Nominal insulation thickness Nominal insulation screen thickness Nominal sheath thickness AAAC/1120 support conductor size Nominal overall diameter Weight Continuous current rating, A
Still air 1m/s wind 2m/s wind
mm^2 mm mm mm mm No/mm mm kg/km A A A
6.35/11kV Aerial Bundled Cable
3x35 6.9  3.4 0.8 1.2 7/4.75 52.4 1370 110 155 185
3x50 8.1 3.4 0.8 1.2 7/4.75 54.6 1530 130 185 225
3x70 9.7 3.4 0.8 1.2 7/4.75 57.8 1790 160 235 280
3x95 11.4 3.4 0.8 1.2 7/4.75 61.3 2100 195 285 345
3x120 12.8 3.4 0.8 1.2 19/3.50 67.3 2540 230 335 405
3x150 14.2 3.4 0.8 1.2 19/3.50 70.1 2840 255 380 460
3x185 15.7 3.4 0.8 1.2 19/3.50 73.1 3190 295 440 530
12.7/22kV Aerial Bundled Cable
3x35 6.9 5.5 0.8 1.2 7/4.75 61 1780 110 155 180
3x50 8.1 5.5 0.8 1.2 7/4.75 63.3 1970 130 185 220
3x70 9.7 5.5 0.8 1.2 7/4.75 66.5 2260 160 230 275
3x95 11.4 5.5 0.8 1.2 7/4.75 69.9 2600 195 285 335
3x120 12.8 5.5 0.8 1.2 19/3.50 75.9 3070 225 330 395
3x150 14.2 5.5 0.8 1.2 19/3.50 78.7 3390 255 375 450
3x185 15.7 5.5 0.8 1.2 19/3.50 81.7 3760 290 435 520
 

Construction


Phase Conductor Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen Extruded semi-conductive layer.
Insulation XLPE.
Insulation Screen Extruded semi-conductive layer.
Outer Sheath HDPE.
Support Conductor Aluminium alloy conductor (AAAC/1120).
Assembly Three XLPE insulated cores are bundled around the AAAC/1120 support conductor in a right hand lay.



15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 015kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 115kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 2


ABOUT US


15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 3


Projects


15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 5

Partner

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 715kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 8



Why US?

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 4

FAQ

Q‌.Key advantages over standard ABC cables?

A. 60% higher span capacity (up to 300m spans),   30% reduced sag under load, Maintains ABC's safety with full insulation

Q‌. Typical applications?

A. River/valley crossings in rural electrification, Temporary power for construction sites, urban areas requiring compact line layouts

Q.Temperature rating?
A. Operates at -40°C to 90°C (95°C short-circuit tolerance), matching ACSR thermal properties

Q‌.Maintenance requirements?
A. Annual checks for: Corrosion at steel-aluminum interfaces, Insulation cracks (especially at suspension points), Neutral conductor integrity

Q‌. Cost comparison vs traditional options?

A. 20% cheaper than separate ACSR+ABC systems, 40% lower lifetime cost than bare ACSR (reduced maintenance)


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zhongdong Cable Co., Ltd.
Location Yingli Development Zone, Jinzhou City, Hebei Province, China
Contact Person Bai

Request A Quote

Please check your email address.
Your message must be at least 20 characters.