STA Armored MV Power Cable 8.7/15kV Single Core XLPE PVC for Construction Overhead Underground Power Stations
STA Armored MV Power Cable 8.7/15kV Single Core XLPE PVC for Construction Overhead Underground Power Stations
Application
These cables have the advantage of simplicity in construction, lightness in weight; onvenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
Construction
Conductor: Tightly press round conductor
Conductor Screen:Semi-conductive shield
Insulation:XLPE
Insulation shield:Semi-conductive shield
Metal shielding layer:Copper tape: Copper Wire:35kV above 500mm2
Binder tape:Non-woven fabrics
Isolation sleeve:Polyvinyl chloride(PVC)
Armour:Non-magnetic steel wire
Outer sheath:Polyvinyl chloride (PVC)
Characteristic
Voltage Rating Uo/U(UM)
3.6/6(7.2)kV 6/6(7.2)kV 6/10(12)kV 8.7/10(12)kV 8.7/15(17.5)kV 12/20(24)kV
18/20(24)kV 18/30(36kV ) 21/35(40.5)kV 26/35(40.5)kV
Maximum operating temperature of conductor:+90℃
Operating ambient temperature: -15℃~+55℃
Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
Minimum Bending Radius
Single core:15D
Multicire: 12D
(D is the actual outer diameter of the cable)
Parameter
|
Specs mm² |
Conductor diameter mm |
Nominal thickness of insulation ±1.0mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
|
Specs mm² |
Conductor diameter mm |
Nominal thickness of insulation ±1.0mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
|
1×50 |
7.6±0.2 |
312 |
43.5 |
3713 |
|
3x50 |
3x50 |
3x50 |
3x50 |
3x50 |
|
1×70 |
9.2±0.2 |
32.8 |
45.2 |
4091 |
|
3x70 |
3x70 |
3x70 |
3x70 |
3x70 |
|
1×95 |
10.9±0.2 |
34.5 |
46.9 |
4499 |
|
3x95 |
3x95 |
3x95 |
3x95 |
3x95 |
|
1×120 |
12.2±0.2 |
35.8 |
48.4 |
4893 |
|
3x120 |
3x120 |
3x120 |
3x120 |
3x120 |
|
1×150 |
13.6±0.2 |
372 |
50.1 |
5317 |
|
3x150 |
3x150 |
3x150 |
3x150 |
3x150 |
|
1×185 |
15.2±0.2 |
38.8 |
51.7 |
5798 |
|
3x185 |
3x185 |
3x185 |
3x185 |
3x185 |
|
1×240 |
17.4±0.2 |
41.0 |
53.9 |
6544 |
|
3x240 |
3x240 |
3x240 |
3x240 |
3x240 |
|
1×300 |
19.5±0.2 |
43.1 |
56.4 |
7375 |
|
3x300 |
3x300 |
3x300 |
3x300 |
3x300 |
|
1×400 |
22.0±0.2 |
45.6 |
59.2 |
8392 |
|
3x400 |
3x400 |
3x400 |
3x400 |
3x400 |
|
1×500/35 |
24.8±0.2 |
492 |
65.4 |
10198 |
|
3x500/35 |
3x500/35 |
3x500/35 |
3x500/35 |
3x500/35 |
|
1×630/35 |
28.2±0.2 |
52.6 |
69.1 |
11876 |
|
3x630/35 |
3x630/35 |
3x630/35 |
3x630/35 |
3x630/35 |
|
1×800/35 |
34.0±0.2 |
58.4 |
76.9 |
15153 |
|
|
|
|
|
|
This table shows 21/36kv data, for more voltage, please contact us for details
About us
Application
Package
Partner
FAQ
What types of cables do you manufacture?
Can you customize cables according to our specific requirements?
What is your production capacity?
What quality certifications do you hold?
What is the lead time for cable manufacturing?
What is your payment and shipping policy?
What is your warranty policy?
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.