Beijing Hui Tong High Tech Limited.
                                                                                                           
Verified Supplier
16 Years
Since 2010
Menu

Desktop Network Bluetooth Enterprise Router NE40E-X8A CR5B0BKP0873 Integrated Chassis HVDC Components Including 2 Fan Tray

Price Negotiable
Price: CN¥722.02/pieces 1-1 pieces
MOQ: Negotiable
Delivery Time: Negotiable
Brand: /
Product Description
Product Description
Specification
Part Number
02351CCF
Model
CR5B0BKP0873
Description
NE40E-X8A Integrated Chassis HVDC Components(Including 2 Fan Tray)
First supported version
V800R009C10SPC200
Technical Specifications
Height [mm]
930 mm
Depth [mm]
650 mm
Wide [mm]
442 mm
Chassis height [U]
21U
Weight without packaging (full configuration) [kg(lb)]
[400G bundle] 184.3 kg (406.31 lb) [1T bundle] 206.5 kg (455.25 lb)
Weight without packaging [kg(lb)]
74.5 kg (164.24 lb)
Typical power consumption (with configuration) [W]
4110 W (fully configured with LPUF-240s) 4770 W (fully configured with LPUF-480s) 6520 W (fully configured with LPUI-1Ts)
Maximum power consumption (with configuration) [W]
6080 W (fully loaded with LPUF-240s) 7110 W (fully loaded with LPUF-480s) 9500 W (fully loaded with LPUI-1Ts)
Typical heat dissipation (with configuration) [BTU/hour]
13334.6 BTU/hour (fully configured with LPUF-240s) 15475.9 BTU/hour (fully configured with LPUF-480s) 21153.6 BTU/hour (fully
configured with LPUI-1Ts)
Power supply mode
HVDC
Input voltage range [V]
192 to 288V,264 to 400V
Rated input voltage [V]
240V/380V
Maximum input current [A]
14 A/single-module
Number of slots
12
Number of service board slots
8
Switching capacity [bps,bit/s]
25.16 Tbit/s (LPUI-1T)
Redundant Switch fabrics
3+1
Redundant fans
[400G bundle] 2 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
[1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
Redundant MPUs
1:1
Redundant power supply
[400G bundle] 3+3 [1T bundle] 4+1
Noise at normal temperature (acoustic power) [dB(A)]
NEBS-compliance (< 78 dBA @ 27°C (80.6°F))
Maximum number of power chassis inputs
(4 channels/PEM)*2 PEMs = (1 channel/PM)*4 PMs*2 PEMs = 8 channels
Maximum input cable size
2.5 mm²
Front-end circuit breaker/fuse
14 A/single-module [400G bundle] HVDC device: 6 PMs, with a total of 6 channels of 14 A [1T bundle] HVDC device: 8 PMs, with a
total of 8 channels of 14 A
Long-term operating temperature [°C(°F)]
0°C to 45°C (32°F to 113°F)
Storage temperature [°C(°F)]
–40°C to +70°C (–40°F to +158 °F)
Short-term operating temperature [°C(°F)]
–5°C to +55°C (23°F to 131°F)
Restriction on the operating temperature variation rate [°C(°F)]
≤ 0.5°C/min (32.9°F/min), non-condensing
Long-term operating relative humidity [RH]
5% RH to 85% RH, non-condensing
Storage relative humidity [RH]
5% RH to 95% RH, non-condensing
Short-term operating relative humidity [RH]
5% RH to 95% RH, non-condensing
Storage altitude [m(ft.)]
< 5000 m (16404.2 ft.)
Long-term operating altitude [m(ft.)]
≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by
1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.)
MTBF [year]
22.32
MTTR [hour]
0.5
Availability
0.999997443
Product Description
Company Profile
Packing & Delivery
FAQ
hotselling
Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Hui Tong High Tech Limited.
Location Room 2311, Kunyu International Center, No. 53 Guanshan Avenue,Wuhan,Hubei, China
Contact Person Jack Long

Request A Quote

Please check your email address.
Your message must be at least 20 characters.