ADMAG AXF010G AXG050 AXF100 Magnetic Water Flowmeter Yokogawa Electromagnetic Flow Meter
ADMAG AXF010G AXG050 AXF100 Magnetic Water Flowmeter Yokogawa Electromagnetic Flow Meter
Product Description:
Introducing the Yokogawa Electromagnetic Flow Meter, an instrument of exceptional precision and reliability. Engineered to excel in various industrial applications, it delivers accurate flow measurements with advanced electromagnetic technology. Its robust construction ensures durability and long-term performance, even in the most demanding environments. Experience unparalleled accuracy and efficiency with this distinguished flow meter.
| Parameter | Yokogawa ADMAG AXF010G | Yokogawa ADMAG AXG050 | Yokogawa ADMAG AXF100 | Typical Competitor (e.g., ABB FSM4000) |
|---|---|---|---|---|
| Measurement Principle | Electromagnetic (Faraday’s Law) | Electromagnetic | Electromagnetic | Electromagnetic |
| Nominal Diameter Range | DN 2.5 – DN 400 mm | DN 25 – DN 1000 mm | DN 25 – DN 2000 mm | DN 3 – DN 2000 mm |
| Accuracy | ±0.35% of reading | ±0.2% of reading | ±0.2% of reading | ±0.2% of reading |
| Fluid Conductivity | ≥ 5 μS/cm | ≥ 5 μS/cm | ≥ 5 μS/cm | ≥ 5 μS/cm |
| Process Temperature | –10 to +120 °C | –20 to +180 °C | –20 to +180 °C | –20 to +180 °C |
| Pressure Rating | Up to 1.6 MPa | Up to 4.0 MPa | Up to 4.0 MPa | Up to 4.0 MPa |
| Output Signals | 4–20 mA, Pulse, HART | 4–20 mA, Pulse, HART, Modbus | 4–20 mA, Pulse, HART, Modbus | 4–20 mA, Pulse, HART, Profibus |
| Lining Materials | PTFE, PFA, Rubber | PTFE, PFA, Rubber | PTFE, PFA, Rubber | PTFE, PFA, Rubber |
| Electrode Materials | SUS316L, Hastelloy, Titanium | SUS316L, Hastelloy, Titanium | SUS316L, Hastelloy, Titanium | SUS316L, Hastelloy, Platinum |
| Ingress Protection | IP67 / IP68 | IP67 / IP68 | IP67 / IP68 | IP67 / IP68 |
| Applications | Small pipelines, dosing | Water, wastewater, general industry | Large pipelines, water distribution | Water, wastewater, chemical, and power |
Applications of Electromagnetic Flowmeters
Water & Wastewater Treatment
- Monitoring raw water intake, distribution, and effluent discharge
- Measuring flow in sewage treatment plants and desalination facilities
- Leak detection and network balancing in municipal water systems
Chemical & Process Industries
- Accurate dosing of acids, alkalis, and other conductive chemicals
- Corrosion‑resistant linings (PTFE, PFA) for aggressive fluids
- Integration with process control systems for continuous monitoring
Food & Beverage
- Hygienic measurement of milk, beer, juices, and other conductive liquids
- CIP (Clean‑in‑Place) compatibility for sanitary operations
- High repeatability for batching and blending processes
Oil, Gas & Petrochemical
- Flow measurement of conductive slurries, emulsions, and wastewater streams
- Monitoring injection water and cooling water circuits
- Explosion‑proof models for hazardous areas
Automotive & Industrial Manufacturing
- Cooling water flow monitoring in engine and battery testing
- Process water and chemical dosing in production lines
- Integration with automation systems for efficiency tracking
Power Generation & Energy
- Boiler feedwater and cooling water flow measurement
- Monitoring condensate return and auxiliary systems
- Reliable operation under high temperature and pressure conditions
FAQ – Yokogawa ADMAG Electromagnetic Flowmeters
1. What is an electromagnetic flowmeter?
An electromagnetic flowmeter (magmeter) measures the flow of conductive liquids using Faraday’s Law of Electromagnetic Induction. It has no moving parts, making it highly reliable and low‑maintenance.
2. Which fluids can be measured?
Any conductive liquid with conductivity above approximately 5 μS/cm, including water, wastewater, slurries, chemicals, beverages, and process fluids. Non-conductive fluids, such as oils or gases, cannot be measured.
3. What are the main advantages of ADMAG flowmeters?
- High accuracy (up to ±0.2% of reading)
- Wide size range (DN 2.5 to DN 2000 mm)
- Robust linings and electrode materials for harsh conditions
- Multiple communication protocols (HART, Modbus, Profibus)
- Proven Yokogawa reliability and global service support
4. Where are these flowmeters typically used?
- Water and wastewater treatment
- Chemical and process industries
- Food and beverage production
- Power generation and energy systems
- Automotive and industrial manufacturing
5. What installation conditions are required?
- Full pipe conditions (the pipe must be filled with liquid)
- Straight pipe lengths upstream and downstream (typically 5D/2D)
- Proper grounding and shielding to avoid electrical noise
6. What maintenance is needed?
Minimal. Since there are no moving parts, maintenance is limited to periodic calibration checks, electrode cleaning (if scaling occurs), and verification of electronics.
7. What outputs and communication options are available?
Standard outputs include 4–20 mA, pulse, and frequency signals, with digital communication options such as HART, Modbus, and Profibus depending on the model.
8. How do ADMAG AXF and AXG models differ?
- AXF Series: Designed for general industrial and water applications, with enhanced accuracy and durability.
- AXG Series: Next‑generation smart magmeters with advanced diagnostics, digital integration, and higher performance for critical processes.
9. What certifications are available?
Models can be supplied with CE, ISO, ATEX/IECEx, and sanitary approvals, depending on the application requirements.
10. How do I select the right model?
Selection depends on pipe size, fluid conductivity, process temperature/pressure, lining and electrode materials, and communication needs. Yokogawa provides sizing tools and engineering support for proper selection.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.