480kva Modular Ups Power Supply Online Three Phase Uninterruptible Power Supply
Price:
Negotiable
MOQ:
1PC
Delivery Time:
8 work days
Brand:
kimoems or OEM
Product Description
480kva Modular Ups Power Supply 60kw Power Module
Power range
50~600kVA
Operation
3P/3P,Online double conversion
Applications
Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
Characteristics
* Fully digital control, flexible and robust.
* 7 &10 inch touch LCD, with IoT functions.
* High reliability and environment adaptability, with protection of components level.
* Intelligent system self-diagnosis, rich fault recording, large capacity of history record storage space.
* Maximum system capacity up to 1.8MVA, the best solution for mega data center
| Model | KM240/60 | KM360/60 | KM480/60 | KM600/50 | KM600/60 |
|---|---|---|---|---|---|
| Rate Power | 240kVA | 360kVA | 480kVA | 600kVA | 600kVA |
| Input | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) |
| Rate Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Rate Freq. | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Input PF | >0.99 | >0.99 | >0.99 | >0.99 | >0.99 |
| Current distortion | THDi(<3% (100% Linear load) | THDi(<3% (100% Linear load) | THDi(<3% (100% Linear load) | THDi(<3% (100% Linear load) | THDi(<3% (100% Linear load) |
| Voltage range | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC (L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC (L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC (L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC (L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC (L-L) power derate from 100% to 75% |
| Freq. range | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz |
| Battery Rate voltage | ±240VDC | ±240VDC | ±240VDC | ±240VDC | ±240VDC |
| Charging capacity | 20%*Pout | 20%*Pout | 20%*Pout | 20%*Pout | 20%*Pout |
| Charging accuracy | ±1% | ±1% | ±1% | ±1% | ±1% |
| Bypass Rate voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Voltage range | Range: -40%~ +25%, Settable, default:-20%~ +15% | Range: -40%~ +25%, Settable, default:-20%~ +15% | Range: -40%~ +25%, Settable, default:-20%~ +15% | Range: -40%~ +25%, Settable, default:-20%~ +15% | Range: -40%~ +25%, Settable, default:-20%~ +15% |
| Overload | 125%< load <130%, 10mins; 130%<load <150%,1min; >150%,300ms | 125%< load <130%, 10mins; 130%<load <150%,1min; >150%,300ms | 125%< load <130%, 10mins; 130%<load <150%,1min; >150%,300ms | 125%< load <130%, 10mins; 130%<load <150%,1min; >150%,300ms | 125%< load <130%, 10mins; 130%<load <150%,1min; >150%,300ms |
| Inverter Rate voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Rate Freq. | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Output PF | 1 | 1 | 1 | 1 | 1 |
| Voltage accuracy | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Load response | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) |
| Recovery time | < 20ms (0% - 100% -0% step load) | < 20ms (0% - 100% -0% step load) | < 20ms (0% - 100% -0% step load) | < 20ms (0% - 100% -0% step load) | < 20ms (0% - 100% -0% step load) |
| Output THDu | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) |
| Overload | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms |
| Frequency accuracy | 0,1% | 0,1% | 0,1% | 0,1% | 0,1% |
| Synchronize window | Settable, ±0.5Hz-±1.5Hz, default±3Hz | Settable, ±0.5Hz-±1.5Hz, default±3Hz | Settable, ±0.5Hz-±1.5Hz, default±3Hz | Settable, ±0.5Hz-±1.5Hz, default±3Hz | Settable, ±0.5Hz-±1.5Hz, default±3Hz |
| Slew rate | Settable, 0.5Hz/S-5Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-5Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-5Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-5Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-5Hz/S, default 0.5Hz/S |
| Crest rate | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Phase factor Accuracy | 120°±0,5° | 120°±0,5° | 120°±0,5° | 120°±0,5° | 120°±0,5° |
| Efficiency | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% |
| Display | LED + 7 inch touch LCD | LED + 7 inch touch LCD | LED + 10 inch touch LCD | LED + 10 inch touch LCD | LED + 10 inch touch LCD |
| Certification Safety | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 |
| Certification EMS | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) |
| IP degree | IP20 | IP20 | IP20 | IP20 | IP20 |
| Configuration | USB, RS232, RS485, Dry contact, Cold start, Air filter | USB, RS232, RS485, Dry contact, Cold start, Air filter | USB, RS232, RS485, Dry contact, Cold start, Air filter | USB, RS232, RS485, Dry contact, Cold start, Air filter | USB, RS232, RS485, Dry contact, Cold start, Air filter |
| Option | SNMP card, AS400 card, Parallel kit, SPD, LBS | SNMP card, AS400 card, Parallel kit, SPD, LBS | SNMP card, AS400 card, Parallel kit, SPD, LBS | SNMP card, AS400 card, Parallel kit, SPD, LBS | SNMP card, AS400 card, Parallel kit, SPD, LBS |
| Environment | 0-40°C(operation); -25°C-70°C(storage); 0-95% (Humidity, non-condensing ) | 0-40°C(operation); -25°C-70°C(storage); 0-95% (Humidity, non-condensing ) | 0-40°C(operation); -25°C-70°C(storage); 0-95% (Humidity, non-condensing ) | 0-40°C(operation); -25°C-70°C(storage); 0-95% (Humidity, non-condensing ) | 0-40°C(operation); -25°C-70°C(storage); 0-95% (Humidity, non-condensing ) |
| Noise(dB)(1 meter) | 72dB @ 100% load, 69dB @ 45% load | 72dB @ 100% load, 69dB @ 45% load | 72dB @ 100% load, 69dB @ 45% load | 72dB @ 100% load, 69dB @ 45% load | 72dB @ 100% load, 69dB @ 45% load |
| Dimension Cabinet(WDH)mm | 600*1000*2000 | 1200*1000*2000 | 1200*1100*2000 | 1200*1100*2000 | 1200*1100*2000 |
| Module(WDH)mm | 442*659*174 | 442*659*174 | 442*659*174 | 442*659*174 | 442*659*174 |
| Weight(kg) Cabinet | 248 | 350 | 578 | 578 | 578 |
| Module | 41 | 41 | 41 | 41 | 41 |
| Power Module rated capacity | 60KW | 60KW | 60KW | 50KW | 60KW |