1-10kVA Rack Mount UPS High Efficiency 98.5% PF0.8 or PF1.0
Price:
Negotiable
MOQ:
5pcs
Delivery Time:
Negotiable
Brand:
kimoems or OEM
Product Description
High-Frequency Rack-Mount Series H1KR-H10KR(L)
Product Features
High efficiency (up to 98.5%)
IGBT rectification technology
Compact and reliable structure
Electrical isolation
High overload capability
LCD display
Product Profile
Power Range: 1-10 kVA
Operation Mode: Single input single output (1-10 kVA)
Applications: Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, industrial and commercial taxation, healthcare, energy, power, and other industries.
Product Characteristics
True online dual conversion
Compatible with generator input (generator capacity must be twice the UPS capacity)
Wide input voltage range (110-300 V), suitable for harsh grid environments (1-10 kVA)
Auto-restart after power recovery when battery is depleted in battery mode
MCU chip control
ECO energy-saving mode
Optional maintenance bypass switch (6-10 kVA models)
Add-on output isolation transformer available (installed before delivery)
Standard EPO (Emergency Power Off) for 6-10 kVA models
Two versions available: PF0.8 and PF1.0
Compact size, user-friendly operation, high power density, strong stability, cost-effective, and widely applicable
Parameters
| Model | H1KR | H2KR | H3KR | H6KR(L) | H10KR(L) |
| Capacity | 1kVA/1kW | 2kVA/2kW | 3kVA/3kW | 6kVA/6kW | 10kVA/10kW |
| Input | |||||
| Voltage Range | |||||
| Min. Transfer Voltage | 180VAC/160VAC/140VAC/120VAC±5% (Ambient temp. <35°C) (Based on load % 100-80 / 80-70 / 70-60 / 60-0) |
110VAC±3% @ 50% load; 176VAC±3% @ 100% load |
|||
| Min. Recovery Voltage | 195VAC/175VAC/155VAC/135VAC±5% (Ambient temp. <35°C) (Based on load % 100-80 / 80-70 / 70-60 / 60-0) |
Min. Transfer Voltage +10V | |||
| Max. Transfer Voltage | 300VAC±5% | 300VAC±3% | |||
| Max. Recovery Voltage | 290VAC±5% | Max. Transfer Voltage -10V | |||
| Frequency Range | 40Hz~70Hz | 46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system |
|||
| Phase | Single Phase, Grounded | ||||
| Power Factor | ≥0.99 @ 220-230 VAC (Input Voltage) | None | |||
| Output | |||||
| Output Voltage | 208/220/230/240VAC | ||||
| Line Regulation | ±1% (Battery Mode) | ||||
| Freq. Range (Sync Range) | 47~53 Hz or 57~63 Hz | 46Hz~54Hz @ 50Hz system; | |||
| Freq. Range (Batt Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||
| Overload | Ambient temperature less than 35°C: 105%~110%: UPS in battery mode will automatically shut down after 10 minutes, or switch to bypass mode if input is normal. 110%~130%: UPS in battery mode will automatically shut down after 30 seconds, or switch to bypass mode if input is normal. 130%~150%: UPS in battery mode will automatically shut down after 3 seconds, or switch to bypass mode if input is normal. >150%: UPS shuts down immediately. |
AC Mode: 100%~110%: 30 minutes; 110%~130%: 5 minutes; >130%: 10 seconds Battery Mode: 100%~110%: 3 minutes; 110%~130%: 30 seconds; >130%: 10 seconds |
|||
| Crest Factor | 3:01 | ||||
| THD | 3% THD (Linear Load); 6% THD (Non-linear Load) |
3% (Linear Load); 5% (Non-linear Load) |
|||
| Transfer Time | |||||
| Line to Battery | 0ms | ||||
| Inverter to Bypass | 4ms (Standard conditions) | 0ms | |||
| Waveform (Batt Mode) | Pure Sine Wave | None | |||
| Efficiency | |||||
| Line Mode | 88% | 89% | 90% | >92% | >93% |
| Battery Mode | 83% | 85% | 88% | >90% | >91% |
| Battery | |||||
| Standard Model | 12V/9AH | 12V/7 Ah or 12V/9 Ah | |||
| Batt Qty (Std) | 2 | 3 | 4 | 6 | 16 20 |
| Charge Current (Std) | 1A | Preset: 1A ± 10%; Max: 1A or 2A selectable | |||
| Charge Voltage (Std) | 273VDC ± 1% 41.0VDC ± 1% |
54.7 VDC ± 1% | 82.0 VDC ± 1% | 218.4V ± 1% 273V ± 1% | |
| Long Runtime Model | Subject to application | Varies by application | |||
| Batt Qty (Long) | 3 | 6 | 6 | 16-20 | |
| Charge Current (Long) | 1A/2A/4A/6A | Preset: 4A ± 10%; Max: 1A, 2A, 4A or 6A selectable (Only for 16 battery units) | |||
| Charge Voltage (Long) | 41.0VDC ± 1% | 82.1VDC ± 1% | 218.4V ± 1% (Based on 16 batteries) | ||
| Physical Specs | |||||
| Std Model Dimensions (DxWxH mm) | 310 x 438 x 88 | 410 x 438 x 88 | 630 x 438 x 88 | ||
| Std Model Net Weight (kg) | 12 | 14.1 | 19 | 29.3 | |
| Long Model Dimensions (DxWxH mm) | 310 x 438 x 88 | 410 x 438 x 88 | 410 x 438 x 88 | 530 x 438 x 88 | |
| Long Model Net Weight (kg) | 9 | 12 | 14.2 | 13 | 17 |
| Environment | |||||
| Operating Humidity | 20-90 % RH @ 0~40°C (Non-condensing) | <95 % RH (Non-condensing) | |||
| Noise | < 50dBA @ 1 meter | < 58dB @ 1 Meter | |||
| Operating Temperature | None | 0~40°C (Battery life shortened at >25°C) | |||
| Operating Altitude | None | <1000m** | |||
| Communication | |||||
| Intelligent RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | ||||
| Optional SNMP | Supports power management via SNMP manager and web browser | ||||
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Hefei Kimo Electrical Co.,Ltd
Location
Building 3, Tuoji Park, No.691, Chang jiang West Road, Shushan District, Hefei, Anhui Province
Contact Person
Emma