Leduv Curing Lamp/LED Multi Head Inkjet Printer Dedicated Curing Lamp
Basic Info.
Model NO.:OL-8060-9-P1-A-2-0
Shape:Disc-shaped
Wavelength:UV-A
Product Light Output Size:80*60mm/
Main Peak Wavelength:385/395nm
Chip Brand:Seoul/San an/LG
Heat Dissipation Method:Circulating Water Cooling
Optical Power Intensity:25000MW/Cm²
Installation Dimensions:According to Requirements
Model:Ol-8060-9-P1-a-2-0
HS Code:0101101010
Product Description
Usage and Maintenance
The cooling temperature and temperature difference of the cooling water tank can be set through the water tank panel, and the cooling temperature and temperature difference can be appropriately set
It can prevent LED UV lights from condensation due to excessive temperature difference.
1. It is recommended to use pure water as the coolant, and antifreeze should be used in low temperature environments and replaced regularly to prevent scale formation. It is recommended that users replace the water once a month. When changing water, do not fill it up first and turn it on to see if there is an alarm prompt.
2. Regularly check if the water flow is normal, bend the water pipe when the machine is turned on to see if there is an alarm prompt. Release the alarm to eliminate it, indicating normal operation.
3. When the ambient temperature is below 5 degrees Celsius, please add antifreeze. The ratio of antifreeze to water is about 1:4.
4. The chassis must be placed facing upwards to avoid the compressor from not working properly.
3, Common faults
1. Over temperature alarm; If the water temperature exceeds the upper or lower limit of the high temperature setting, add chilled water/room temperature water or shut down for treatment.
2. Flow failure; Flow switch/water pump malfunction or low water volume, replace the flow switch or check if the water circuit is unobstructed.
3. Liquid level alarm; If the liquid level switch is damaged or the liquid level is low, replace the liquid level switch or add appropriate liquid.
4. Low temperature alarm; Add constant temperature water