60 KW 60 KVA Programmable AC Load With Dual Voltage ( 400 V 190 V ) Three-phase RCD Protection Touch-screen Operation

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: 20-25 working days
Brand: Jianhong
Product Description
60 KW 60 KVA Programmable AC Load With Dual Voltage ( 400 V 190 V ) Three-phase RCD Protection Touch-screen Operation
Product Features
  1. Flexible and precise load simulation

    The power factor is adjustable between 0.7 and 1.0, enabling precise simulation of load characteristics across various real-world power grids.

    Provide high-precision step adjustment (customizable according to actual needs) for precise load setting.

  2. Three-phase testing capability

    It supports both three-phase independent loading and unbalanced loading, enabling accurate simulation of complex field operating conditions and testing the equipment's performance under three-phase imbalance conditions.

    It supports automatic one-touch switching between AC 400V (three-phase) and 190V (three-phase) ratings, compatible with equipment testing across various voltage standards.

  3. Industrial-grade reliability and durability

    Equipped with a forced air cooling system (bottom-inlet, top-outlet), it ensures stable operation of the equipment under continuous full-load conditions 24/7 and is specifically designed for long-term aging tests.

    The core resistor component has a design lifespan of up to 15 years, and the entire unit features a robust structure that meets stringent industrial environment requirements.

  4. Intelligent Control and Integration

    Equipped with a high-definition touchscreen for intuitive and convenient local operation, with parameter settings and real-time monitoring clearly displayed.

  5. Convenient mobility and deployment

    The device features industrial casters at its base, enabling easy mobility between laboratories, workshops, or various testing locations.

    The terminal blocks feature a copper busbar design, ensuring robust and reliable connections that meet high-current testing requirements.

Application Scenarios
  1. Testing and Verification of Power Generation Equipment

    Generators: Used for factory testing and power verification

  2. Uninterruptible Power Supply System Testing

    UPS testing—including load capacity, output accuracy, conversion efficiency, and battery discharge performance—is a critical step in the acceptance process for data center and server room equipment.

    Inverter: Verify its rated output power, overload capacity, and adaptability to nonlinear loads; suitable for photovoltaic and energy storage systems.

  3. Research and Development of Power Electronics and Industrial Equipment

    Switching power supplies/frequency converters: During the R&D phase, aging tests, load adjustment rate tests, and extreme operating condition simulations were conducted.

    Transformer: Perform temperature rise tests, efficiency tests, and load capacity evaluations.

  4. Certification and Quality Inspection

    Third-party testing laboratory: Conducts compliance load tests for power equipment in accordance with industry standards (e.g., IEC, UL).

    Production Line: As the final step in factory inspection, it ensures that each unit meets performance requirements under rated load conditions.

Frequently Asked
Q: Can I test single-phase equipment?
A: Yes, this device supports single-phase independent loading and can be tested using any single-phase device.
Q: Is remote control software provided?
A: We provide a complete Modbus communication protocol. You can use any standard industrial control software (e.g., LabVIEW) or your own system for control, and we will provide technical support.
Q: What about the warranty and after-sales service?
A: We offer a 12-month warranty and lifetime technical support, including remote assistance via email or video calls, as well as spare parts.
Product parameters
Product Parameter norms
model JH-RCD-60KWA400A190-P-RS
brand Jianhong
Size (Depth * Width * Height) 1620*861*1850MM
weight ≤500KG
rated voltage Switch between AC 400V (three-phase four-wire) and AC 190V (three-phase four-wire).
power rating

three-phase R year:60KW RCD year:60KVA

single-phase R year:20KW RCD year:20KVA

accessory power supply AC 220V
power factor The adjustable range of 0.7–1 is satisfied, with a precision step size of 0.05.
Resistance Precision ±3%
Capacitance accuracy ±10%
Cold Verification Method Mandatory air cooling; intake from the bottom, outlet from the top; speed-regulating fan
work environment Working environment temperature: -10°C to 50°C, dry and well-ventilated
Local Control Method touch screen
Remote Control Method compatible Modbus TCP RS485
IP grade IP20 (Indoor Environment)
Display Mode Displays load voltage, current, power, power factor, etc. (0.5-digit precision)
RS Resistance Level Amutually:30Ω,15Ω,8Ω,4Ω,2Ω,1Ω,0.8Ω,0.4Ω,0.2Ω
Bmutually:30Ω,15Ω,8Ω,4Ω,2Ω,1Ω,0.8Ω,0.4Ω,0.2Ω
Cmutually:30Ω,15Ω,8Ω,4Ω,2Ω,1Ω,0.8Ω,0.4Ω,0.2Ω
R Load Resistance Level Amutually:50W,100W,200W,200W,500W,1KW,2KW,2KW,5KW,10KW
Bmutually:50W,100W,200W,200W,500W,1KW,2KW,2KW,5KW,10KW
Cmutually:50W,100W,200W,200W,500W,1KW,2KW,2KW,5KW,10KW
Capacitor Level Amutually:100µF,200µF,470µF,470µF,1mF,2.2mF,4.7mF,4.7mF,10mF,20mF
Bmutually:100µF,200µF,470µF,470µF,1mF,2.2mF,4.7mF,4.7mF,10mF,20mF
Cmutually:100µF,200µF,470µF,470µF,1mF,2.2mF,4.7mF,4.7mF,10mF,20mF
Load Protection

Overvoltage, overcurrent, high-temperature alarm, fan failure alarm, emergency stop, audio-visual indication, operating status display

Automatic Adjustment Range Description

Power capacity range: 50 W–20 kW (single-phase, step size 50 W); 150 W–60 kW (three-phase, step size 150 W). RCD capacity range: 1 KVA–20 KVA (single-phase, step size 100 V); 3 KVA–60 KVA (three-phase, step size 300 V).

direction for use

1. The three phases can be loaded independently, enabling unbalanced three-phase loading.

2. Switching between R-load and RCD mode is supported.

3. The maximum voltage margin is set at 1.1 times the rated voltage; higher testing requirements may only be achieved for short-term use.

operate mode

It can operate continuously online with a 7*24-hour working schedule, and the resistor has a service life of 15 years.

noise

At a distance of one meter, the level is less than 85 dB.

Load Connection Method

bronze medal

Auxiliary Power Supply Method

line bank

Box Color

Computer White DH-1928

Move Method

Wheeled type

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Jianhong Jitai Technology Co., Ltd.
Location 6th Floor, Building C, Pengyifa Science and Technology Park, Baihua Community, Guangming New District, Shenzhen, Guangdong Province,China
Contact Person Golden Yu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.