Product Description
WZ-200D SMT Reflow Oxygen Analyzer
Advanced oxygen content analyzer featuring double zirconia sensor technology for precise measurement in SMT reflow processes with 1ppm resolution and fast 30-second response time.
Key Product Features
- Imported double zirconia sensor for high measurement accuracy and fast response
- Extended calibration cycle with minimal maintenance requirements
- Operates in air environments without affecting sensor lifespan
- Ultra-sensitive measurement capability down to 1ppm
- Wide AC power supply range (85-264V) for versatile applications
- Single-point calibration ensures accuracy across entire measurement range
- Built-in temperature automatic compensation for stable performance
- No reference gas required, unaffected by ambient oxygen concentration
- Intuitive user interface with menu-driven operation
- Bidirectional communication capability with host computer systems
- Built-in imported sampling pump with configurable operating modes
Technical Specifications
| Parameter | Specification |
|---|---|
| Measurement Principle | Zirconia Sensor Technology |
| Display | 128x64 Dot Matrix LCD |
| Measuring Range | 0~10/100/1000ppm/1.00%/25.00% |
| Resolution | 1ppm |
| Repeatability | ≤±1% |
| Response Time | T≤30 Seconds |
| Analog Output | 4-20mA DC (non-isolated) or 0~10V DC |
| Communication Interface | RS232 (default) or RS485 |
| Power Supply | AC 85-264V 50/60Hz |
| Sample Temperature Range | -10°C to +50°C |
| Sample Gas Flow Rate | 400-600ml/min |
| Dimensions (WxHxD) | 258mm x 130mm x 300mm |
| Panel Cutout Size | 238mm x 132mm |
| Sensor Service Life | >12 months (normal operating conditions) |
| Gas Connection | NPT 1/8 Internal Thread |
| Installation Method | Embedded Panel Mount |
Application & Installation
The WZ-200D supports multiple sampling methods including extraction type, ejection type, and ejection style. Compatible with micro positive pressure, micro negative pressure, or normal pressure systems. Suitable for background gases including N₂ and inert gas mixtures.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Global Soul Limited
Location
Room 205, 2/F, Bldg B, Tengjun Tech Park, Buxin K Rd, Area 73, Buxin, Xin'an, Bao'an, Shenzhen
Contact Person
Yi Lee