Rexroth A10VSO Series Hydraulic Pump
A10VSO100DFR/31R-VKC62N00 A10VSO100DFR/31R-VSA12N00 A10VSO100DFR/31R-PPA12N00 A10VSO100FHD/31R-PPA12N00 A10VSO100DRG/31R-PPA12N00 German mining hydraulic pump Rexroth axial variable piston pump
Product Specifications
Attribute Value
Model No A4VSO71DFR/10R-PPB13K31-S1738
Series a2fo
Drive Mode Mechanically Driven Pump
Weight 12-50 kg
Type No AA10VSO71DFR1/31R-VPA42N00
Inlet Connection Threaded or Flanged
Maximum Pressure 315 bar
Shaft Seal Type Radial Shaft Seal
Technical Features
Key Specifications
  • Displacement: 100 cm³/rev (Fixed displacement design)
  • Max Pressure: 350 bar (continuous), Peak: 400 bar
  • Speed Range: 800-3600 rpm (Dependent on lubrication conditions)
  • Fluid Compatibility: Mineral oil (ISO VG 46-68), Temp range: -20°C to +80°C
  • Efficiency: ≥92% (volumetric), Tested per ISO 4409
Functional Components
  • Housing: Aluminum alloy (hardness: HB 90-120)
  • Rotating Group: Ceramic-coated pistons for reduced wear
  • Control Mechanism: Pressure compensator (DFR) or load-sensing (EP) options
  • Seals: NBR/FKM materials (valid date: 10 years from manufacture)
Troubleshooting Guide
Insufficient or No Oil Output
  • Causes: Clogged oil filter, low oil level, air leakage, internal pump leakage, small inclination angle, motor reversal
  • Solutions: Clean filter, add oil, check seals, replace worn parts, adjust variable piston, correct motor phase sequence
High Vibration and Noise
  • Mechanical Causes: Misalignment, damaged coupling, loose bolts, bearing wear
  • Hydraulic Causes: Restricted inlet, clogged filter, high viscosity
  • Solutions: Realign components, replace damaged parts, select proper oil, ensure smooth piping
Pump Overheating
  • Causes: Improper mechanical clearance, high-pressure leakage, filter blockage
  • Solutions: Adjust gaps, increase cooling capacity, clean/replace filter
Maintenance Guidelines
  • Maintain oil temperature at 25-60℃ with cleanliness level ≥8
  • Conduct comprehensive inspections every 6 months (seals, filters, components)
  • Check oil replenishment pump status after 3000 hours of operation
  • Always prime pump before starting to prevent dry friction
Installation Requirements
  • Pump/motor shaft concentricity <0.05mm
  • Maximum suction height: 500mm
  • Use original seals and wear-resistant components for replacements
Rexroth A10VSO Series Hydraulic Pump - Industrial Application
Quality Assurance
Inspection Criteria
  • IQC: Dimensional checks per DWG-100-01 (tolerance ±0.05mm)
  • IPQC: Leakage test at 1.5x rated pressure (15-min hold)
  • OQC: Noise level ≤75 dB(A) at 1500 rpm
Note: Critical defects include seal failure and pressure drop >10%
Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.