Product Description
Rexroth A4VSO250 Variable High-Pressure Industrial Piston Pump
Product Models

A4VSO250DFR/22R-VPB25N00, A4VSO250DFR/22R-VZB13N00, A4VSO250DFR/22R-PZB13N00, A4VSO250DFR/22R-VPB13N00, A4VSO250DFR/22R-PPB13N00

Product Specifications
Brand:
Rexroth
Displacement:
250
Control Mode:
DR
Purpose:
Hydraulic System
Scope of Use:
Excavator, Coal Mining Industry, Ship Hydraulic Systems
Warranty:
1 Year
Rexroth A4VSO250 Industrial Piston Pump
Related Part Numbers
Part Number Description
R902488470 AA4VSO250DFR/30R-PPB25U99
R902414682 AA4VSO250DFR/30R-PZB13N00
R902482098 AA4VSO250DFR/30R-PZB25U24
R902447402 AA4VSO250DFR/30R-VPB13N00
R910986137 AA4VSO250DFR1/30R-PPB13K35
R902416271 AA4VSO250DFR1/30R-PPB13K68
R902411474 AA4VSO250DFR1/30R-PPB13N00
R902415860 AA4VSO250DFR1/30R-PZB13K33
R910984938 AA4VSO250DFR1/30R-PZB13K35
R910984940 AA4VSO250DFR1/30R-PZB13N00
Contact Information
WhatsApp:
+85267220981
Maintenance & Troubleshooting
Daily/Regular Maintenance
  • Keep the pump exterior clean from dust and oil
  • Check oil levels before start-up and during operation
  • Listen for abnormal noises during operation
  • Regularly record operating parameters (pressure, flow, temperature)
  • Change fluid filters periodically (every 1000 hours or as needed)
  • Check and replace worn or aged seals
  • Follow lubrication requirements
  • Inspect the coupling for looseness or wear
Insufficient Flow or No Flow

Possible causes:

  • Insufficient inflow due to high suction line resistance, low oil level, excessive pump speed, or clogged inlet
  • Excessive leakage from worn internal parts (pistons, cylinder block, port plate)
  • Swash plate angle set too small
Flow Output at Neutral Control Signal

Typically caused by control mechanism being off its neutral point due to misadjustment, looseness, or damage. Solution involves re-zeroing, tightening, or replacing the controller.

Fluctuating Output Flow

Often related to control piston mechanism issues caused by contamination, weak/damaged control amplifier spring, or other damaged components. Requires disassembly for inspection and possible part replacement.

External Oil Leaks

Potential leak sources:

  • Shaft seal damage or wear
  • Loose hose connections or damaged fittings
  • Leaks from variable mechanism cover bolts
  • Case imperfections (rare)
  • High case pressure from excessive internal leakage
Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.