Rexroth A4VSO250 Variable Piston Pump 280 Bar Max Pressure
Price:
2
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
Rexroth A4VSO Series Variable Piston Pump
Product Models
A4VSO250LR2G/22R-VPB25N00, A4VSO250LR2G/22R-VZB13N00, A4VSO355DR/22R-PZB13N00, A4VSO180EO1/22R-VZB13N00, A4VSO180EO1/22R-VPB25N00
Product Description
German industrial high-pressure variable piston pump from Rexroth's A4VSO series.
Contact: WhatsApp +85267220981 | Email: yli97584@gmail.com
| Brand Name | Rexroth |
|---|---|
| Place of Origin | Fujian, China |
| Warranty | 12 Months |
| Video outgoing-inspection | Provided |
| Machinery Test Report | Provided |
| Application | Machinery Repair Shops |
| Material | Iron |
| Condition | Original |
| Quality | 100% Tested Great Performance |
| Certification | ISO |
| Feature | Long Life, Low Noise |
| Function | Filter Diesel Oil |
| Power | Hydraulic Power |
| Payment Term | T/T 100% |
Compatible Part Numbers
| Part Number | Model |
|---|---|
| R902429768 | AA4VSO250DFE1/30R-PPB25K35 |
| R902459361 | AA4VSO250DFE1/30R-PPB25KB3 |
| R902456424 | AA4VSO250DFE1/30R-PPB25N00 |
Frequently Asked Questions
Operation & Fluid Management
What hydraulic oil should I use, and what is the optimal viscosity?
- Oil Types: Recommended fluids include mineral oils (RC 90220), environmentally friendly fluids (RC 90221), and HF fluids (HFA, HFB, HFC - check seal compatibility, typically FKM for HFD; RC 90223). Specify the fluid type when ordering.
- Viscosity Range: The optimal operating viscosity range (at operating temperature) is 16 to 36 mm²/s. Absolute limits are:
- Minimum: 10 mm²/s (short-term, max. case drain temp 90°C)
- Maximum: 1000 mm²/s (short-term, cold start)
- Selection: Select a viscosity grade (e.g., VG 46, VG 68) so that the viscosity at the operating temperature (typically tank temperature in open circuits) falls within the optimal range. Generally, opting for a higher viscosity grade is advised.
What are the fluid cleanliness requirements?
To ensure reliable operation and long service life, the oil cleanliness should be at least NAS 1638 Class 9 or ISO/DIS 4406 18/15.
Why does my pump get overheated?
Common causes for excessive heating include:
- Internal Leakage: Excessive internal leakage within the pump components converts hydraulic energy to heat.
- Mechanical Friction: Dry or semi-dry friction due to worn parts or inadequate lubrication generates heat.
- Fluid Friction: Inadequate tank capacity or cooling, causing the system to overheat.
- Clogged Return Line Filter: A blocked return filter creates high backpressure, leading to increased temperature.
- Low Oil Level: Insufficient oil in the reservoir reduces cooling capacity.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location
Nan'an, Fujian Province, China
Contact Person