Rexroth A4VSO180 Variable Displacement Piston Pump 280 Bar Pressure
Price:
2
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
Rexroth A4VSO180 Axial Piston Pump - High Pressure Industrial Variable
Product Models
A4VSO180EO1/22R-PPB13N00, A4VSO180LR2/22R-VPB25N00, A4VSO180LR2/22R-VZB13N00,
A4VSO180LR2/22R-PZB13N00, A4VSO180LR2/22R-VPB13N00
A4VSO180LR2/22R-PZB13N00, A4VSO180LR2/22R-VPB13N00
Product Specifications
| Brand Name | Rexroth |
|---|---|
| Place of Origin | Fujian, China |
| Warranty | 12 Months |
| Video Outgoing-Inspection | Provided |
| Machinery Test Report | Provided |
| Application | Machinery Repair Shops |
| Material | Iron |
| Condition | Original |
| Quality | 100% Tested Great Performance |
| Certification | ISO |
| Feature | Long Life, Low Noise |
| Function | Filter Diesel Oil |
| Power | Hydraulic Power |
| Payment Term | T/T 100% |
Product Image
Part Numbers
| Part Number | Model |
|---|---|
| R902561168 | AA4VSO180DFE1Z/30R-VZB25U68 |
| R902468024 | AA4VSO180DFEH/30R-FZB25U99 |
| R902426831 | AA4VSO180DFEH/30R-VZB13KD3-SO576 |
Frequently Asked Questions
Selection
Select a viscosity grade (e.g., VG 46, VG 68) so that the viscosity at the operating temperature (typically tank temperature in open circuits) falls within the optimal range. Generally, opting for a higher viscosity grade is advised.
Fluid Cleanliness Requirements
To ensure reliable operation and long service life, the oil cleanliness should be at least NAS 1638 Class 9 or ISO/DIS 4406 18/15.
Pump Overheating Causes
- Internal Leakage: Excessive internal leakage within the pump components converts hydraulic energy to heat.
- Mechanical Friction: Dry or semi-dry friction due to worn parts or inadequate lubrication generates heat.
- Fluid Friction: Inadequate tank capacity or cooling, causing the system to overheat.
- Clogged Return Line Filter: A blocked return filter creates high backpressure, leading to increased temperature.
- Low Oil Level: Insufficient oil in the reservoir reduces cooling capacity.
Maintenance & Troubleshooting
Daily/Regular Maintenance
- Keep the pump exterior clean from dust and oil.
- Check oil levels before start-up and during operation.
- Listen for abnormal noises during operation, which may indicate internal issues like part wear or looseness.
- Regularly record operating parameters like pressure, flow, and temperature to monitor health.
- Change fluid filters periodically (e.g., every 1000 hours or as per conditions).
- Check and replace worn or aged seals.
- Follow lubrication requirements for various points.
- Inspect the coupling for looseness or wear.
Insufficient Flow Causes
- Insufficient Inflow: Caused by high suction line resistance, low oil level, excessive pump speed, or a clogged inlet strainer/suction line.
- Excessive Leakage: Worn internal parts (pistons, cylinder block, port plate) leading to high internal leakage.
- Swash Plate Angle: The swash plate angle might be set too small, minimizing displacement.
Contact Information
WhatsApp: +85267220981 | Email: yli97584@gmail.com
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location
Nan'an, Fujian Province, China
Contact Person
liyun