MOOG Electro-Hydraulic Servo Valve Series
D661-4594C, D661-4624, D661-4636, D661-4640, D661-4649, D661-4650, D661-4651, D661-4652, D661-4691C, D661-4697C
Product Specifications
| Parameter | Value |
|---|---|
| Rated Current | 1A |
| Voltage | 24V / 220V |
| Power | 0.1 kW |
| Brand | MOOG |
| Place of Origin | Germany |
| Application | LED touch control |
| Material | PVC, Steel, Copper |
| Rated Frequency | 50 Hz |
| Type | Servo proportional valve |
| Control | Electro hydraulic/Proportional |
| Construction Material | Advanced alloy steel/cast iron |
Compatible Models
Original MOOG: D661-2057, D661-205A, D661-318A, D661-363, D661-363A, D661-363D, D661-3702E, D661-4020B, D661-423A, D661-4491E, D661-450C, D661-450D-4, D661-473B, D661-4744, D661-4793, D661-515A, D661-5718, D661-5729, D661Z1718F, D661Z2742F, D661Z2743H, D661Z3726E, D661Z5604, D661Z6716, D661Z671C, D661Z736A, D662-1714G, D662-1942E, D662-2714E, D662-4348K, D662-5704, D662-580A, D662-5NC, D662-Z917G, D662E957A, D662Z4719B, D662Z902B, D663-1902E, D663-2709E, D663-344C, D663-344K, D663-363C, D663-4002, D663-5002, D663-814A, D663Z1713M, D663Z2706EF, D663Z270H, D663Z2770H, D663Z4712B, D663Z703G, D663Z954AB, D663Z954B, D663Z954C, D664-2708E, D664-375K, D664-519, D664-5302, D664-757A, D664E209C, D664Z1905F, D664Z4710B, D665-4007D, D665E5004, D682Z4706B, D682Z4709B, D682Z4809, D682Z4809G, D684E4715, D684Z4715B, D684Z47245, D684Z4724B, D684Z4733F, D684Z4815, D684Z4857G, D684Z4862, D688Z4701D, D688Z4701E, D688Z4702A, D688Z4705B, D691-2090D, D691Z2086D, D733-7368, D760-026A, D760-103A, D760-317A, D760-503A, D760-505A, D760-506A, D760-858A, D760-880A, D760-938A, D761-104, D761-2620, D761-532, D761-883, D765-1601, D770-801
Installation Requirements
- Filtration: Install a precision filter with a rating of 5 microns or less upstream of the servo valve. Maintain hydraulic fluid cleanliness at maximum ISO DIS 4406 Code 16/13 (Code 14/11 recommended).
- System Flushing: Thoroughly flush the entire hydraulic system before installation to remove contaminants. Use a flushing manifold and circulate fluid under normal operation conditions.
- Mounting: Can be mounted in any orientation with proper port alignment. Ensure mounting surface is clean, smooth, and flat. Torque screws to 96 inch-pounds.
- Connections: Use O-ring seal connections (SAE J1926). Prefer crimped or 24-degree cone type connections over welded fittings.
Troubleshooting Guide
| Symptom | Possible Causes |
|---|---|
| Servovalve does not follow input command | 1. Open coil or coil leads 2. Clogged inlet filter |
| Poor response | 1. Clogged inlet orifices or nozzles 2. Partially clogged filter 3. "Sticky" spool |
| No response to electrical signal | Shorted coil assembly |
| Low flow gain | 1. Incorrect null adjustment 2. Partially plugged orifice or filter |
Maintenance Guidelines
- Hydraulic Fluid: Maintain recommended cleanliness level. Change oil every six months and keep temperature between 40°C to 50°C.
- Filters: Monitor pressure drop across filters and replace elements periodically or when pressure drop becomes excessive.
- Regular Inspection: Check for electrical faults, mechanical failures (stuck valve spool, damaged springs, worn seals), and hydraulic issues (oil contamination, leaks).